Worked example

5-inch lift cylinder in regeneration

Compare selected-cycle time with the standard time, then compare regenerative push force with the force a loaded lift requires.

Inputs

in
in
in
psi
GPM
psi
Regeneration joins rod-side flow to pump flow at the cap port.

Anatomy

Double-acting cylinder cutaway
Double-acting cylinder cutawayPUSH FORCE23.2klbfPULL FORCE31.7klbfEXTEND SPEED7.89in/sCYCLE TIME9sPumpCap chamberRod flow to capPressureReturnTank / suctionTrapped rod pressure / rating96.97%0%100% reference150%

Results

US customary

Regeneration feeds both ports during extend. Compare the reduced push force with the actual load before using a regenerative stroke.

Standard push force54,977.871lbf
Pull force31,749.721lbf
Regenerative push force23,228.151lbf
Standard extend speed3.333in/s84.667mm/s
Regenerative extend speed7.89in/s200.395mm/s
Retract speed5.772in/s146.609mm/s
Selected extend + retract9s
Standard cycle time14.197s
Regenerative cycle time9s
Ideal trapped rod pressure4,848.485psi
Cap area19.635in²
Rod-side annulus area11.339in²
Cap-to-annulus area ratio1.732:1
2:1 area checkOutside 2.5% of 2:1

Worked calculation

  1. Piston areas

    A_cap = πB²/4. A_rod = πd²/4. A_annulus = A_cap − A_rod.

  2. Force and speed

    Standard push = P × A_cap, pull = P × A_annulus. Speed = Q/A at the fed port. Regenerative push = P × A_rod and extend speed = Q/A_rod because pressure acts at both ports.

  3. Cycle time and equal speeds

    Time = stroke/v_extend + stroke/v_retract. A 2:1 cap-to-annulus area ratio gives equal regenerative extend and retract speeds. The check uses a ±2.5% tolerance.

  4. Trapped pressure

    P_rod = P_cap × A_cap/A_annulus for ideal static balance with a blocked rod port. External load, dynamic spikes and backpressure can change the actual pressure.

Results for the original example inputs
Cap area19.635in²
Rod-side annulus area11.339in²
Standard push force54,977.871lbf
Regenerative push force23,228.151lbf
Selected extend + retract9s
Ideal trapped rod pressure4,848.485psi

Uses constant pump flow and gauge working pressure. Standard force estimates assume negligible return pressure and friction. Cycle time covers the two strokes and excludes dwell, ramping and valve switching.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.