Worked example

48-inch carriage travel

At constant flow, stroke length scales cycle time while bore and annulus area set peak speed and force.

Inputs

in
in
in
psi
GPM
psi
Regeneration joins rod-side flow to pump flow at the cap port.

Anatomy

Double-acting cylinder cutaway
Double-acting cylinder cutawayPUSH FORCE21.2klbfPULL FORCE15.9klbfEXTEND SPEED3.601in/sCYCLE TIME23.32sPumpCap chamberRod chamberPressureReturnTank / suctionTrapped rod pressure / rating73.33%0%100% reference150%

Results

US customary
Standard push force21,166.481lbf
Pull force15,874.86lbf
Regenerative push force5,291.62lbf
Standard extend speed3.601in/s91.477mm/s
Regenerative extend speed14.406in/s365.907mm/s
Retract speed4.802in/s121.969mm/s
Selected extend + retract23.324s
Standard cycle time23.324s
Regenerative cycle time13.328s
Ideal trapped rod pressure2,933.333psi
Cap area9.621in²
Rod-side annulus area7.216in²
Cap-to-annulus area ratio1.333:1
2:1 area checkOutside 2.5% of 2:1

Worked calculation

  1. Piston areas

    A_cap = πB²/4. A_rod = πd²/4. A_annulus = A_cap − A_rod.

  2. Force and speed

    Standard push = P × A_cap, pull = P × A_annulus. Speed = Q/A at the fed port. Regenerative push = P × A_rod and extend speed = Q/A_rod because pressure acts at both ports.

  3. Cycle time and equal speeds

    Time = stroke/v_extend + stroke/v_retract. A 2:1 cap-to-annulus area ratio gives equal regenerative extend and retract speeds. The check uses a ±2.5% tolerance.

  4. Trapped pressure

    P_rod = P_cap × A_cap/A_annulus for ideal static balance with a blocked rod port. External load, dynamic spikes and backpressure can change the actual pressure.

Results for the original example inputs
Cap area9.621in²
Rod-side annulus area7.216in²
Standard push force21,166.481lbf
Regenerative push force5,291.62lbf
Selected extend + retract23.324s
Ideal trapped rod pressure2,933.333psi

Uses constant pump flow and gauge working pressure. Standard force estimates assume negligible return pressure and friction. Cycle time covers the two strokes and excludes dwell, ramping and valve switching.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.