Worked example
2:1 regenerative transfer cylinder
The rod is close to bore/√2. Regenerative extend and standard retract therefore use nearly equal effective areas and run at nearly equal speeds.
Inputs
Anatomy
Double-acting cylinder cutawayResults
US customaryRegeneration feeds both ports during extend. Compare the reduced push force with the actual load before using a regenerative stroke.
| Standard push force | 25,132.741lbf |
|---|---|
| Pull force | 12,566.612lbf |
| Regenerative push force | 12,566.13lbf |
| Standard extend speed | 4.289in/s108.946mm/s |
| Regenerative extend speed | 8.579in/s217.897mm/s |
| Retract speed | 8.578in/s217.888mm/s |
| Selected extend + retract | 4.197s |
| Standard cycle time | 6.295s |
| Regenerative cycle time | 4.197s |
| Ideal trapped rod pressure | 3,999.923psi |
| Cap area | 12.566in² |
| Rod-side annulus area | 6.283in² |
| Cap-to-annulus area ratio | 2:1 |
| 2:1 area check | Within 2.5% of 2:1 |
Worked calculation
Piston areas
A_cap = πB²/4. A_rod = πd²/4. A_annulus = A_cap − A_rod.
Force and speed
Standard push = P × A_cap, pull = P × A_annulus. Speed = Q/A at the fed port. Regenerative push = P × A_rod and extend speed = Q/A_rod because pressure acts at both ports.
Cycle time and equal speeds
Time = stroke/v_extend + stroke/v_retract. A 2:1 cap-to-annulus area ratio gives equal regenerative extend and retract speeds. The check uses a ±2.5% tolerance.
Trapped pressure
P_rod = P_cap × A_cap/A_annulus for ideal static balance with a blocked rod port. External load, dynamic spikes and backpressure can change the actual pressure.
| Cap area | 12.566in² |
|---|---|
| Rod-side annulus area | 6.283in² |
| Standard push force | 25,132.741lbf |
| Regenerative push force | 12,566.13lbf |
| Selected extend + retract | 4.197s |
| Ideal trapped rod pressure | 3,999.923psi |
Uses constant pump flow and gauge working pressure. Standard force estimates assume negligible return pressure and friction. Cycle time covers the two strokes and excludes dwell, ramping and valve switching.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.