Dilute a half-full 20-gallon hydroponic reservoir

A 20-gallon tank has ten gallons at 2.0 mS/cm. Tap water measures 0.3 mS/cm, so equal volumes of nutrient solution and tap water are being mixed.

Inputs

Conductivity converter

Enter a reading on the selected scale. Calculation supports 0–20 mS/cm.

Reservoir and top-off
US gal
US gal
mS/cm
mS/cm
mS/cm
Nutrient recipe
mL/US gal
mL/US gal
mL/US gal

Results

Estimated EC after top-off

1.15 mS/cm

Volume-weighted conductivity estimate

Meter reading in EC
2 mS/cm
500-scale PPM (NaCl)
1,000 ppm
700-scale PPM (KCl)
1,400 ppm
Top-off needed
10 US gal
Added solution EC to hit target
0.3 mS/cm
Part A concentrate
40 mL
Part B concentrate
40 mL
Supplement concentrate
10 mL

Concentrate per batch

Amounts use the selected mixing volume and label rates.

Concentrate needed for this batchPart A: 40 mL. Part B: 40 mL. Supplement: 10 mLPart A40 mLPart B40 mLSupplement10 mL

Worked calculation

  1. Convert the displayed meter scale

    2 ÷ 1 = 2 mS/cm. Multiply by 500 or 700 for each PPM display.

  2. Find how much liquid to add

    20 US gal − 10 US gal = 10 US gal

  3. Weight EC by both volumes

    (37.854 L × 2 + 37.854 L × 0.3) ÷ 75.708 L = 1.15 mS/cm

  4. Solve for the added solution EC

    (75.708 L × 1.15 − 37.854 L × 2) ÷ 37.854 L = 0.3 mS/cm

  5. Calculate concentrate for each label rate

    10 US gal × each label dose gives 40 / 40 / 10 mL (A / B / supplement).

What the example shows

The halfway blend estimates 1.15 mS/cm. Measuring the filled tank after circulation is especially useful if the tap water composition varies.

How the model works

The 500 and 700 numbers are meter scale factors. Actual dissolved mass depends on the ions present. Compare recipes and meters on a common EC scale and use temperature-compensated readings.

The weighted top-off model is an approximation, especially when solutions contain different salts. Enter the final measured EC of the added solution as a separate input. Follow the product label, dilute each concentrate into water separately and measure EC after mixing.

References

Common questions

Should I use the same dilution math for 10 gallons of RO water?

Enter the measured RO water conductivity. Ten gallons at nearly zero EC would take the equal-volume mixture close to 1.0 mS/cm.

Why let a half-full reservoir circulate before measuring?

A recently poured top-off can create uneven concentration near the inlet. Circulation lets the sample reflect the combined tank.