Dilute a half-full 20-gallon hydroponic reservoir
A 20-gallon tank has ten gallons at 2.0 mS/cm. Tap water measures 0.3 mS/cm, so equal volumes of nutrient solution and tap water are being mixed.
Inputs
Results
Estimated EC after top-off
Volume-weighted conductivity estimate
- Meter reading in EC
- 2 mS/cm
- 500-scale PPM (NaCl)
- 1,000 ppm
- 700-scale PPM (KCl)
- 1,400 ppm
- Top-off needed
- 10 US gal
- Added solution EC to hit target
- 0.3 mS/cm
- Part A concentrate
- 40 mL
- Part B concentrate
- 40 mL
- Supplement concentrate
- 10 mL
Concentrate per batch
Amounts use the selected mixing volume and label rates.
Inputs used
- Meter scale
- EC (mS/cm)
- Meter reading
- 2
- Final reservoir volume
- 20 US gal
- Volume already in reservoir
- 10 US gal
- Existing solution EC
- 2 mS/cm
- Added water or feed EC
- 0.3 mS/cm
- Target final EC
- 1.15 mS/cm
- Mixing volume
- Top-off only
- Part A label dose
- 4 mL/US gal
- Part B label dose
- 4 mL/US gal
- Supplement label dose
- 1 mL/US gal
Worked calculation
- Convert the displayed meter scale
2 ÷ 1 = 2 mS/cm. Multiply by 500 or 700 for each PPM display.
- Find how much liquid to add
20 US gal − 10 US gal = 10 US gal
- Weight EC by both volumes
(37.854 L × 2 + 37.854 L × 0.3) ÷ 75.708 L = 1.15 mS/cm
- Solve for the added solution EC
(75.708 L × 1.15 − 37.854 L × 2) ÷ 37.854 L = 0.3 mS/cm
- Calculate concentrate for each label rate
10 US gal × each label dose gives 40 / 40 / 10 mL (A / B / supplement).
What the example shows
The halfway blend estimates 1.15 mS/cm. Measuring the filled tank after circulation is especially useful if the tap water composition varies.
How the model works
The 500 and 700 numbers are meter scale factors. Actual dissolved mass depends on the ions present. Compare recipes and meters on a common EC scale and use temperature-compensated readings.
The weighted top-off model is an approximation, especially when solutions contain different salts. Enter the final measured EC of the added solution as a separate input. Follow the product label, dilute each concentrate into water separately and measure EC after mixing.
References
Common questions
Should I use the same dilution math for 10 gallons of RO water?
Enter the measured RO water conductivity. Ten gallons at nearly zero EC would take the equal-volume mixture close to 1.0 mS/cm.
Why let a half-full reservoir circulate before measuring?
A recently poured top-off can create uneven concentration near the inlet. Circulation lets the sample reflect the combined tank.