Why a nearly full 40-gallon reservoir cannot reach target EC
A 40 US gallon tank has 38 gallons remaining at 2.4 mS/cm. The grower has 0.2 EC top-off water and would like to reach 1.8 mS/cm.
Inputs
Results
Estimated EC after top-off
Your goal is below the minimum possible with this top-off volume.
- Meter reading in EC
- 2 mS/cm
- 500-scale PPM (NaCl)
- 1,000 ppm
- 700-scale PPM (KCl)
- 1,400 ppm
- Top-off needed
- 2 US gal
- Added solution EC to hit target
- —
- Part A concentrate
- 8 mL
- Part B concentrate
- 8 mL
- Supplement concentrate
- 2 mL
Concentrate per batch
Amounts use the selected mixing volume and label rates.
Inputs used
- Meter scale
- EC (mS/cm)
- Meter reading
- 2
- Final reservoir volume
- 40 US gal
- Volume already in reservoir
- 38 US gal
- Existing solution EC
- 2.4 mS/cm
- Added water or feed EC
- 0.2 mS/cm
- Target final EC
- 1.8 mS/cm
- Mixing volume
- Top-off only
- Part A label dose
- 4 mL/US gal
- Part B label dose
- 4 mL/US gal
- Supplement label dose
- 1 mL/US gal
Worked calculation
- Convert the displayed meter scale
2 ÷ 1 = 2 mS/cm. Multiply by 500 or 700 for each PPM display.
- Find how much liquid to add
40 US gal − 38 US gal = 2 US gal
- Weight EC by both volumes
(143.846 L × 2.4 + 7.571 L × 0.2) ÷ 151.416 L = 2.29 mS/cm
- Solve for the added solution EC
(151.416 L × 1.8 − 143.846 L × 2.4) ÷ 7.571 L = negative EC (target is unreachable by top-off)
- Calculate concentrate for each label rate
2 US gal × each label dose gives 8 / 8 / 2 mL (A / B / supplement).
What the example shows
Adding the two gallons gives about 2.29 mS/cm. Even at zero EC, the added volume is too small. Model a partial replacement by lowering the existing-volume input.
How the model works
The 500 and 700 numbers are meter scale factors. Actual dissolved mass depends on the ions present. Compare recipes and meters on a common EC scale and use temperature-compensated readings.
The weighted top-off model is an approximation, especially when solutions contain different salts. Enter the final measured EC of the added solution as a separate input. Follow the product label, dilute each concentrate into water separately and measure EC after mixing.
References
Common questions
What does an unavailable required EC mean for the 40-gallon tank?
The equation would require a negative conductivity. A larger replacement volume or different management step is needed to reach the target.
How do I test replacing ten gallons in the nearly full reservoir?
Enter the volume and EC left after draining, then set the final volume to 40 gallons. Enter the replacement solution’s measured EC.