Dose Part A, Part B and supplement in 55 liters

A fresh 55 L batch uses label rates of 3 mL/L for Part A, 2 mL/L for Part B and 0.5 mL/L for a compatible supplement.

Inputs

Conductivity converter

Enter a reading on the selected scale. Calculation supports 0–20 mS/cm.

Reservoir and top-off
L
L
mS/cm
mS/cm
mS/cm
Nutrient recipe
mL/L
mL/L
mL/L

Results

Estimated EC after top-off

1.7 mS/cm

Volume-weighted conductivity estimate

Meter reading in EC
2 mS/cm
500-scale PPM (NaCl)
1,000 ppm
700-scale PPM (KCl)
1,400 ppm
Top-off needed
55 L
Added solution EC to hit target
1.7 mS/cm
Part A concentrate
165 mL
Part B concentrate
110 mL
Supplement concentrate
27.5 mL

Concentrate per batch

Amounts use the selected mixing volume and label rates.

Concentrate needed for this batchPart A: 165 mL. Part B: 110 mL. Supplement: 27.5 mLPart A165 mLPart B110 mLSupplement27.5 mL

Worked calculation

  1. Convert the displayed meter scale

    2 ÷ 1 = 2 mS/cm. Multiply by 500 or 700 for each PPM display.

  2. Find how much liquid to add

    55 L − 0 L = 55 L

  3. Weight EC by both volumes

    (0 L × 0 + 55 L × 1.7) ÷ 55 L = 1.7 mS/cm

  4. Solve for the added solution EC

    (55 L × 1.7 − 0 L × 0) ÷ 55 L = 1.7 mS/cm

  5. Calculate concentrate for each label rate

    55 L × each label dose gives 165 / 110 / 27.5 mL (A / B / supplement).

What the example shows

The label arithmetic gives 165 mL A, 110 mL B and 27.5 mL supplement. Dose each into water in the sequence specified by the product.

How the model works

The 500 and 700 numbers are meter scale factors. Actual dissolved mass depends on the ions present. Compare recipes and meters on a common EC scale and use temperature-compensated readings.

The weighted top-off model is an approximation, especially when solutions contain different salts. Enter the final measured EC of the added solution as a separate input. Follow the product label, dilute each concentrate into water separately and measure EC after mixing.

References

Common questions

Can I prepare the 165 mL Part A and 110 mL Part B in the same cup?

Follow the product mixing instructions. Concentrated A and B can precipitate if combined directly, so meter them separately into water.

What does the 27.5 mL supplement number depend on?

It is the 0.5 mL/L example label rate multiplied by 55 L. Enter your own supplement’s rate and check that it is compatible with the nutrient set.