Worked example

A steep 12 ft route behind a shed

A short route drops 18 in across 12 ft. Compare that grade with both bands and estimate a wider stone section around a 6 in pipe.

Project inputs

Survey and comparison bands
ft
in
Use a negative number if the outlet end is higher.
%
%
%
%
French drain section
in
in
Enter the stone section only. Exclude a soil or sod cap.
in
in
%

Material & layout estimate

Grade toward outlet

12.5%
Slope angle
7.13°
Vertical to horizontal ratio
1 : 8
Lawn grade check
Above band
Patio grade check
Above band
#57 washed stone to order
1 yd³
Gross stone section volume
1 yd³
Perforated pipe length
12.09 ft
Fabric cut width including lap
84 in
Geotextile to wrap the trench
84.65 ft²

Check the actual pipe invert fall and approved outlet separately. Local drainage and accessibility requirements may differ from the comparison bands.

Slope profile & drain trench Schematic
Slope profile & drain trenchGrade toward outlet: 12.5%. Slope angle: 7.13°. Vertical to horizontal ratio: 1 : 8. Lawn grade check: Above band RUN / DROP12.5%StartOutlet12 ft horizontal run18 in dropFRENCH DRAIN SECTION1 yd³16 in trench width6 in perforated pipe

Starting estimate

The grade is above both example bands. A drain takeoff gives material quantities while a site plan addresses erosion and a stable outlet.

Grade toward outlet
12.5%
Vertical to horizontal ratio
1 : 8
Lawn grade check
Above band
Patio grade check
Above band

How the estimate works

  1. Divide the signed drop by the horizontal run in matching units. Multiply by 100 for percent grade or use the arctangent for degrees.
  2. Subtract the cross-sectional area displaced by the pipe from the trench’s stone section. Multiply by the sloped length, then add the order allowance.
  3. Estimate the fabric cut width from the trench perimeter plus the lap. Use that width times the drain length for one continuous wrap.

Questions and answers

What does a 1:8 ratio mean behind the shed?

The grade changes one vertical unit for every eight horizontal units. That corresponds to 12.5%.

Why use the outside diameter of the 6 in drain pipe?

The full outside cross-section displaces stone. A nominal size or inside diameter may differ from the product’s actual outside dimension.