Asymmetric loading bay pair

Enter different directional candela values at the two sight angles for a point off the midpoint of the bay.

Primary ray
cd
ft
ft
ft
Pair and target
ft
Zero uses the primary position only. The second source is at x = spacing.
cd
fc
Horizontal
10.55fc
Radial vert.
5.81fc
Nadir angle
17.6°
Slant distance
23.41ft

Inverse-square ray geometry

Edit inputs ↓
Inverse-square ray geometryRAY SECTIONTWO POSITIONSh 22.31 ftθ 17.6°r 7.1 ftD 23.41 ftHorizontal light10.55 fc
The ray section folds the x and y offsets into radial distance. Vertical readings are radially facing magnitudes.

Horizontal task target

Within screen
OutsideThresholdWithin
  • Direct horizontal light10.55 / ≥ 9.29 fc within screen

Choose a task and a project target appropriate to its IES recommendation.

Additional readings
Primary radial offset7.1ft
Primary horizontal contribution7.3fc
Primary radial vertical contribution2.32fc
Second nadir angle47°
Second slant distance32.73ft
Second horizontal contribution3.25fc
Second radial vertical contribution3.48fc

Worked calculation

US customary results for the original preset.

  1. Combine the two offsets to get a radius of 7.1 ft. The primary slant distance is 23.41 ft at 17.6 °.
  2. Project 4200 cd onto the horizontal plane. The primary group contributes 7.3 fc.
  3. Add 3.25 fc from the second group. The radial-facing vertical total is 5.81 fc.

Calculation method

Read candela at the computed nadir and azimuth from the luminaire file. For the second position, use its own directional candela.

Distance and angle
r = √(dx² + dy²) · D = √(r² + h²) · θ = atan2(r, h)
Horizontal and radial vertical light
Eh = I cos³(θ)/h² · Ev = I cos²(θ) sin(θ)/h²
Superposition
Etotal = m × sum of illuminances at the modeled positions

This direct-light screen omits reflections, obstructions and finite luminaire size. Sum projections onto the actual wall normal for a fixed receiving plane.

Sources and assumptions ↗