Broad architectural flood

Screen the footprint and center light from a wide flood at a wall set back several meters.

Light source
lm
°
Enter an angle below 180°, or exactly 360° for a full sphere.
W
Receiving surface
ft
fc
Intensity
2,221.1cd
Beam center
6.82fc
Beam diameter
41.52ft
Luminance
3.75fL

Solid-angle cone and receiving plane

Edit inputs ↓
Solid-angle cone and receiving planeUNIFORM CONERECEIVING PLANEα 98°Ø 41.52 ftThrow 18.04 ftSolid angle2.161 sr
Cone scale illustrates centerline throw. Full-sphere emission has no finite beam diameter.

Beam center target

Review needed
OutsideThresholdWithin
  • Axial illuminance6.82 / ≥ 8.36 fc outside screen

The target applies on the optical axis.

Additional readings
Luminous flux4,800lm
Solid angle2.161sr
Luminaire efficacy129.73lm/W
Diameter at the receiving plane41.52ft

Worked calculation

US customary results for the original preset.

  1. Convert the full beam angle of 98 ° to 2.161 sr. The uniform-cone relationship pairs 4800 lm with 2221.15 cd.
  2. At a throw of 18.04 ft, the center receives 6.82 fc. The projected cone diameter is 41.52 ft.
  3. Apply diffuse reflectance 0.55 to estimate 3.75 fL at the center.

Calculation method

In the uniform-cone approximation the axial intensity equals the average intensity inside the cone. Real FWHM beam distributions need an IES or LDT file.

Beam solid angle and flux
Ω = 2π(1 − cos(α/2)) · Φ = IΩ · Ωsphere = 4π
Beam footprint and center
Diameter = 2d tan(α/2) · Ecenter = I/d²
Diffuse luminance and efficacy
L = Ecenter × ρ/π · efficacy = Φ/W

Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.

Sources and assumptions ↗