Museum narrow spotlight

Convert catalog lumens to equivalent uniform-cone intensity and estimate the center light on a matte display surface.

Light source
lm
°
Enter an angle below 180°, or exactly 360° for a full sphere.
W
Receiving surface
ft
fc
Intensity
11,634.5cd
Beam center
105.55fc
Beam diameter
3.33ft
Luminance
36.94fL

Solid-angle cone and receiving plane

Edit inputs ↓
Solid-angle cone and receiving planeUNIFORM CONERECEIVING PLANEα 18°Ø 3.33 ftThrow 10.5 ftSolid angle0.077 sr
Cone scale illustrates centerline throw. Full-sphere emission has no finite beam diameter.

Beam center target

Within screen
OutsideThresholdWithin
  • Axial illuminance105.55 / ≥ 41.81 fc within screen

The target applies on the optical axis.

Additional readings
Luminous flux900lm
Solid angle0.0774sr
Luminaire efficacy81.82lm/W
Diameter at the receiving plane3.33ft

Worked calculation

US customary results for the original preset.

  1. Convert the full beam angle of 18 ° to 0.0774 sr. The uniform-cone relationship pairs 900 lm with 11634.46 cd.
  2. At a throw of 10.5 ft, the center receives 105.55 fc. The projected cone diameter is 3.33 ft.
  3. Apply diffuse reflectance 0.35 to estimate 36.94 fL at the center.

Calculation method

In the uniform-cone approximation the axial intensity equals the average intensity inside the cone. Real FWHM beam distributions need an IES or LDT file.

Beam solid angle and flux
Ω = 2π(1 − cos(α/2)) · Φ = IΩ · Ωsphere = 4π
Beam footprint and center
Diameter = 2d tan(α/2) · Ecenter = I/d²
Diffuse luminance and efficacy
L = Ecenter × ρ/π · efficacy = Φ/W

Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.

Sources and assumptions ↗