Matte black receiving panel
Set the ideal diffuse reflectance to zero. Incident illuminance remains positive while estimated surface luminance is zero.
Inputs
View results ↑- Intensity
- 1,800cd
- Beam center
- 29.03fc
- Beam diameter
- 6.05ft
- Luminance
- 0fL
Solid-angle cone and receiving plane
Edit inputs ↓Beam center target
Within screenOutsideThresholdWithin
- Axial illuminance29.03 / ≥ 27.87 fc within screen
The target applies on the optical axis.
Additional readings
| Luminous flux | 751.19lm |
|---|---|
| Solid angle | 0.4173sr |
| Luminaire efficacy | 44.19lm/W |
| Diameter at the receiving plane | 6.05ft |
Worked calculation
US customary results for the original preset.
- Convert the full beam angle of 42 ° to 0.4173 sr. The uniform-cone relationship pairs 751.19 lm with 1800 cd.
- At a throw of 7.87 ft, the center receives 29.03 fc. The projected cone diameter is 6.05 ft.
- Apply diffuse reflectance 0 to estimate 0 fL at the center.
Calculation method
In the uniform-cone approximation the axial intensity equals the average intensity inside the cone. Real FWHM beam distributions need an IES or LDT file.
- Beam solid angle and flux
- Ω = 2π(1 − cos(α/2)) · Φ = IΩ · Ωsphere = 4π
- Beam footprint and center
- Diameter = 2d tan(α/2) · Ecenter = I/d²
- Diffuse luminance and efficacy
- L = Ecenter × ρ/π · efficacy = Φ/W
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.
Sources and assumptions ↗LightingLuxLab · US customary
Matte black receiving panel
Inputs
| Calculate from | Peak intensity · candela |
|---|---|
| Peak intensity | 1,800cd |
| Full beam angle | 42° |
| Electrical input | 17W |
| Axial throw | 7.8740157ft |
| Diffuse reflectance | 0 |
| Center illuminance target | 27.870912fc |
Results
| Intensity | 1,800cd |
|---|---|
| Beam center | 29.03fc |
| Beam diameter | 6.05ft |
| Luminance | 0fL |
| Luminous flux | 751.19lm |
| Solid angle | 0.4173sr |
| Luminaire efficacy | 44.19lm/W |
| Diameter at the receiving plane | 6.05ft |
Beam center target
- Axial illuminance · 29.03 / ≥ 27.87 fc · Within screen
The target applies on the optical axis.
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.