Candela-rated track head

Start with beam-center candela and estimate the equivalent cone flux and efficacy for a track head.

Light source
cd
°
Enter an angle below 180°, or exactly 360° for a full sphere.
W
Receiving surface
ft
fc
Intensity
5,100cd
Beam center
56.34fc
Beam diameter
4.74ft
Luminance
42.82fL

Solid-angle cone and receiving plane

Edit inputs ↓
Solid-angle cone and receiving planeUNIFORM CONERECEIVING PLANEα 28°Ø 4.74 ftThrow 9.51 ftSolid angle0.187 sr
Cone scale illustrates centerline throw. Full-sphere emission has no finite beam diameter.

Beam center target

Within screen
OutsideThresholdWithin
  • Axial illuminance56.34 / ≥ 32.52 fc within screen

The target applies on the optical axis.

Additional readings
Luminous flux951.85lm
Solid angle0.1866sr
Luminaire efficacy39.66lm/W
Diameter at the receiving plane4.74ft

Worked calculation

US customary results for the original preset.

  1. Convert the full beam angle of 28 ° to 0.1866 sr. The uniform-cone relationship pairs 951.85 lm with 5100 cd.
  2. At a throw of 9.51 ft, the center receives 56.34 fc. The projected cone diameter is 4.74 ft.
  3. Apply diffuse reflectance 0.76 to estimate 42.82 fL at the center.

Calculation method

In the uniform-cone approximation the axial intensity equals the average intensity inside the cone. Real FWHM beam distributions need an IES or LDT file.

Beam solid angle and flux
Ω = 2π(1 − cos(α/2)) · Φ = IΩ · Ωsphere = 4π
Beam footprint and center
Diameter = 2d tan(α/2) · Ecenter = I/d²
Diffuse luminance and efficacy
L = Ecenter × ρ/π · efficacy = Φ/W

Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.

Sources and assumptions ↗