Start with beam-center candela and estimate the equivalent cone flux and efficacy for a track head.
Inputs
View results ↑- Intensity
- 5,100cd
- Beam center
- 56.34fc
- Beam diameter
- 4.74ft
- Luminance
- 42.82fL
Solid-angle cone and receiving plane
Edit inputs ↓Beam center target
Within screenOutsideThresholdWithin
- Axial illuminance56.34 / ≥ 32.52 fc within screen
The target applies on the optical axis.
Additional readings
| Luminous flux | 951.85lm |
|---|---|
| Solid angle | 0.1866sr |
| Luminaire efficacy | 39.66lm/W |
| Diameter at the receiving plane | 4.74ft |
Worked calculation
US customary results for the original preset.
- Convert the full beam angle of 28 ° to 0.1866 sr. The uniform-cone relationship pairs 951.85 lm with 5100 cd.
- At a throw of 9.51 ft, the center receives 56.34 fc. The projected cone diameter is 4.74 ft.
- Apply diffuse reflectance 0.76 to estimate 42.82 fL at the center.
Calculation method
In the uniform-cone approximation the axial intensity equals the average intensity inside the cone. Real FWHM beam distributions need an IES or LDT file.
- Beam solid angle and flux
- Ω = 2π(1 − cos(α/2)) · Φ = IΩ · Ωsphere = 4π
- Beam footprint and center
- Diameter = 2d tan(α/2) · Ecenter = I/d²
- Diffuse luminance and efficacy
- L = Ecenter × ρ/π · efficacy = Φ/W
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.
Sources and assumptions ↗LightingLuxLab · US customary
Candela-rated track head
Inputs
| Calculate from | Peak intensity · candela |
|---|---|
| Peak intensity | 5,100cd |
| Full beam angle | 28° |
| Electrical input | 24W |
| Axial throw | 9.5144357ft |
| Diffuse reflectance | 0.76 |
| Center illuminance target | 32.516064fc |
Results
| Intensity | 5,100cd |
|---|---|
| Beam center | 56.34fc |
| Beam diameter | 4.74ft |
| Luminance | 42.82fL |
| Luminous flux | 951.85lm |
| Solid angle | 0.1866sr |
| Luminaire efficacy | 39.66lm/W |
| Diameter at the receiving plane | 4.74ft |
Beam center target
- Axial illuminance · 56.34 / ≥ 32.52 fc · Within screen
The target applies on the optical axis.