Courtyard-facing classroom

Reduce the visible sky angle to model a nearby courtyard facade blocking part of the window’s view.

Room and window
ft
ft
ft
ft²
°
Surfaces and sky
fc
Daylight DF
2.99%
Interior avg.
25.58fc
Glazing/floor
23.33%
Bounding area
2,359.4ft²

Window and visible sky section

Edit inputs ↓
Window and visible sky sectionOVERCAST SKYWINDOW SECTIONθ 31°T 0.65Glass 150.69 ft²Average interior daylight25.58 fc
The sky angle is the unobstructed vertical sky seen from the glazing, measured in degrees.

Daylight adequacy

Within screen
OutsideThresholdWithin
  • Lower daylight band2.99 / ≥ 2 % within screen
  • Upper daylight band2.99 / ≤ 5 % within screen

2–5% · well-daylit screen

Additional readings
Room floor area645.83ft²
Total wall area1,067.78ft²
Horizontal overcast illuminance854.71fc
Daylight screening tier2–5% · well-daylit screen

Worked calculation

US customary results for the original preset.

  1. Add the floor, ceiling, and four walls to get a bounding surface area of 2359.4 ft².
  2. Combine 150.69 ft² of glazing, transmittance 0.65, and 31 ° of visible sky. The simplified DF is 2.99 %.
  3. Multiply 854.71 fc outside by DF/100 to get 25.58 fc average inside. The window-to-floor ratio is 23.33 %.

Calculation method

This simplified split-flux screen uses 1 − Ravg. The published BRE average daylight factor equation uses 1 − Ravg².

Bounding area
Atot = 2(LW + LH + WH)
Simplified daylight factor
DF (%) = T × Aw × θ/[Atot × (1 − Ravg)]
Interior daylight and glazing ratio
Einside = Eovercast × DF/100 · WFR (%) = 100Aw/(LW)

Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.

Sources and assumptions ↗