High-bay perimeter point

Evaluate an industrial point far from the luminaire nadir. Use the lower candela value associated with the more oblique light ray.

Primary ray
cd
ft
ft
ft
Pair and target
ft
Zero uses the primary position only. The second source is at x = spacing.
fc
Horizontal
0.48fc
Radial vert.
0.49fc
Nadir angle
45.2°
Slant distance
37.26ft

Inverse-square ray geometry

Edit inputs ↓
Inverse-square ray geometryRAY SECTIONONE POSITIONh 26.25 ftθ 45.2°r 26.45 ftD 37.26 ftHorizontal light0.48 fc
The ray section folds the x and y offsets into radial distance. Vertical readings are radially facing magnitudes.

Horizontal task target

Review needed
OutsideThresholdWithin
  • Direct horizontal light0.48 / ≥ 9.29 fc outside screen

Choose a task and a project target appropriate to its IES recommendation.

Additional readings
Primary radial offset26.45ft
Primary horizontal contribution0.48fc
Primary radial vertical contribution0.49fc
Second nadir angle—
Second slant distance—
Second horizontal contribution—
Second radial vertical contribution—

Worked calculation

US customary results for the original preset.

  1. Combine the two offsets to get a radius of 26.45 ft. The primary slant distance is 37.26 ft at 45.2 °.
  2. Project 950 cd onto the horizontal plane. The primary group contributes 0.48 fc.
  3. Use the primary group alone. The radial-facing vertical total is 0.49 fc.

Calculation method

Read candela at the computed nadir and azimuth from the luminaire file. For the second position, use its own directional candela.

Distance and angle
r = √(dx² + dy²) · D = √(r² + h²) · θ = atan2(r, h)
Horizontal and radial vertical light
Eh = I cos³(θ)/h² · Ev = I cos²(θ) sin(θ)/h²
Superposition
Etotal = m × sum of illuminances at the modeled positions

This direct-light screen omits reflections, obstructions and finite luminaire size. Sum projections onto the actual wall normal for a fixed receiving plane.

Sources and assumptions ↗