Drive aisle with a higher target

Set a higher project target to screen a driveway with frequent pedestrian crossings. Follow up with a point-by-point grid.

Road and mounting
ft
ft
ft
×
Luminaire and target
lm
fc
W
Pole pitch
122.47ft
Pitch / height
4.15×
Pole density
86.2poles/mi
Linear power
5.52kW/km

Pole elevation and layout plan

Edit inputs ↓
Pole elevation and layout planCURB SECTIONROADWAY PLANH 29.53 ftStaggeredArm 3.94 ftS 122.47 ftMaintained target2.23 fc
Pitch is measured along one side. A staggered arrangement offsets the opposite row by half the pitch.

RP-8 layout screen

Review needed
OutsideThresholdWithin
  • Same-side pitch / height4.15 / ≤ 3.8 × outside screen

Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.

Additional readings
Luminaires per repeat2
Combined light loss factor0.765
Maintained delivered flux per repeat8,421.12lm
Area-normalized connected power0.055W/ft²
Optical overhang3.94ft
Distance to next pole station61.23ft
Pitch limit from height criterion112.2ft

Worked calculation

US customary results for the original preset.

  1. Apply utilization and loss factors over 2 poles per repeat to get 8421.12 lm maintained.
  2. Divide by the road width and target illuminance to get 122.47 ft same-side pitch. The pitch-to-height ratio is 4.15.
  3. Scale the repeat to 86.2 poles/mi and 5.52 kW/km of linear connected power.

Calculation method

Select a maintained illuminance target for the road or parking class. Apply the street-side utilization and light loss to the flux in one repeating roadway cell.

Maintained lumens through one cell
Φcell = Φ × CU × LLD × LDD × fixtures per repeat
Same-side pole pitch
S = Φcell/(Eavg × roadway width)
Pole density and power
Poles/km = 1000 × fixtures per repeat/S · kW/km = poles/km × W/1000

The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.