Museum narrow spotlight
Convert catalog lumens to equivalent uniform-cone intensity and estimate the center light on a matte display surface.
Inputs
View results ↑- Intensity
- 11,634.5cd
- Beam center
- 105.55fc
- Beam diameter
- 3.33ft
- Luminance
- 36.94fL
Solid-angle cone and receiving plane
Edit inputs ↓Beam center target
Within screenOutsideThresholdWithin
- Axial illuminance105.55 / ≥ 41.81 fc within screen
The target applies on the optical axis.
Additional readings
| Luminous flux | 900lm |
|---|---|
| Solid angle | 0.0774sr |
| Luminaire efficacy | 81.82lm/W |
| Diameter at the receiving plane | 3.33ft |
Worked calculation
US customary results for the original preset.
- Convert the full beam angle of 18 ° to 0.0774 sr. The uniform-cone relationship pairs 900 lm with 11634.46 cd.
- At a throw of 10.5 ft, the center receives 105.55 fc. The projected cone diameter is 3.33 ft.
- Apply diffuse reflectance 0.35 to estimate 36.94 fL at the center.
Calculation method
In the uniform-cone approximation the axial intensity equals the average intensity inside the cone. Real FWHM beam distributions need an IES or LDT file.
- Beam solid angle and flux
- Ω = 2π(1 − cos(α/2)) · Φ = IΩ · Ωsphere = 4π
- Beam footprint and center
- Diameter = 2d tan(α/2) · Ecenter = I/d²
- Diffuse luminance and efficacy
- L = Ecenter × ρ/π · efficacy = Φ/W
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.
Sources and assumptions ↗LightingLuxLab · US customary
Museum narrow spotlight
Inputs
| Calculate from | Luminous flux · lumens |
|---|---|
| Luminous flux | 900lm |
| Full beam angle | 18° |
| Electrical input | 11W |
| Axial throw | 10.4986877ft |
| Diffuse reflectance | 0.35 |
| Center illuminance target | 41.806368fc |
Results
| Intensity | 11,634.5cd |
|---|---|
| Beam center | 105.55fc |
| Beam diameter | 3.33ft |
| Luminance | 36.94fL |
| Luminous flux | 900lm |
| Solid angle | 0.0774sr |
| Luminaire efficacy | 81.82lm/W |
| Diameter at the receiving plane | 3.33ft |
Beam center target
- Axial illuminance · 105.55 / ≥ 41.81 fc · Within screen
The target applies on the optical axis.
Use measured photometry for beam edges, off-axis illuminance and non-Lambertian materials.