Reading bay with open sky
Estimate average daylight through a clear window facing a largely unobstructed sky under overcast conditions.
Inputs
View results ↑- Daylight DF
- 6.29%
- Interior avg.
- 70.14fc
- Glazing/floor
- 25.36%
- Bounding area
- 1,500.5ft²
Window and visible sky section
Edit inputs ↓Daylight adequacy
Review neededOutsideThresholdWithin
- Lower daylight band6.29 / ≥ 2 % within screen
- Upper daylight band6.29 / ≤ 5 % outside screen
Above 5% · glare risk screen
Additional readings
| Room floor area | 356.5ft² |
|---|---|
| Total wall area | 787.49ft² |
| Horizontal overcast illuminance | 1,114.84fc |
| Daylight screening tier | Above 5% · glare risk screen |
Worked calculation
US customary results for the original preset.
- Add the floor, ceiling, and four walls to get a bounding surface area of 1500.5 ft².
- Combine 90.42 ft² of glazing, transmittance 0.71, and 75 ° of visible sky. The simplified DF is 6.29 %.
- Multiply 1114.84 fc outside by DF/100 to get 70.14 fc average inside. The window-to-floor ratio is 25.36 %.
Calculation method
This simplified split-flux screen uses 1 − Ravg. The published BRE average daylight factor equation uses 1 − Ravg².
- Bounding area
- Atot = 2(LW + LH + WH)
- Simplified daylight factor
- DF (%) = T × Aw × θ/[Atot × (1 − Ravg)]
- Interior daylight and glazing ratio
- Einside = Eovercast × DF/100 · WFR (%) = 100Aw/(LW)
Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.
Sources and assumptions ↗LightingLuxLab · US customary
Reading bay with open sky
Inputs
| Room length | 23.6220472ft |
|---|---|
| Room width | 15.0918635ft |
| Room height | 10.1706037ft |
| Net glazed area | 90.4168475ft² |
| Visible transmittance | 0.71 |
| Visible sky angle | 75° |
| Mean surface reflectance | 0.49 |
| Outdoor overcast illuminance | 1,114.83648fc |
Results
| Daylight DF | 6.29% |
|---|---|
| Interior avg. | 70.14fc |
| Glazing/floor | 25.36% |
| Bounding area | 1,500.5ft² |
| Room floor area | 356.5ft² |
| Total wall area | 787.49ft² |
| Horizontal overcast illuminance | 1,114.84fc |
| Daylight screening tier | Above 5% · glare risk screen |
Daylight adequacy
- Lower daylight band · 6.29 / ≥ 2 % · Within screen
- Upper daylight band · 6.29 / ≤ 5 % · Outside screen
Above 5% · glare risk screen
Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.