Reading bay with open sky

Estimate average daylight through a clear window facing a largely unobstructed sky under overcast conditions.

Room and window
ft
ft
ft
ft²
°
Surfaces and sky
fc
Daylight DF
6.29%
Interior avg.
70.14fc
Glazing/floor
25.36%
Bounding area
1,500.5ft²

Window and visible sky section

Edit inputs ↓
Window and visible sky sectionOVERCAST SKYWINDOW SECTIONθ 75°T 0.71Glass 90.42 ft²Average interior daylight70.14 fc
The sky angle is the unobstructed vertical sky seen from the glazing, measured in degrees.

Daylight adequacy

Review needed
OutsideThresholdWithin
  • Lower daylight band6.29 / ≥ 2 % within screen
  • Upper daylight band6.29 / ≤ 5 % outside screen

Above 5% · glare risk screen

Additional readings
Room floor area356.5ft²
Total wall area787.49ft²
Horizontal overcast illuminance1,114.84fc
Daylight screening tierAbove 5% · glare risk screen

Worked calculation

US customary results for the original preset.

  1. Add the floor, ceiling, and four walls to get a bounding surface area of 1500.5 ft².
  2. Combine 90.42 ft² of glazing, transmittance 0.71, and 75 ° of visible sky. The simplified DF is 6.29 %.
  3. Multiply 1114.84 fc outside by DF/100 to get 70.14 fc average inside. The window-to-floor ratio is 25.36 %.

Calculation method

This simplified split-flux screen uses 1 − Ravg. The published BRE average daylight factor equation uses 1 − Ravg².

Bounding area
Atot = 2(LW + LH + WH)
Simplified daylight factor
DF (%) = T × Aw × θ/[Atot × (1 − Ravg)]
Interior daylight and glazing ratio
Einside = Eovercast × DF/100 · WFR (%) = 100Aw/(LW)

Use climate-based daylight modeling for certification and a luminance-based analysis for glare. High reflectance can amplify this estimate.

Sources and assumptions ↗