Staggered industrial drive aisle
Alternate poles on opposing curbs. The spacing from one pole station to the next is half the pitch measured along a single curb.
Inputs
View results ↑- Pole pitch
- 188.2ft
- Pitch / height
- 5.46×
- Pole density
- 56.1poles/mi
- Linear power
- 3.87kW/km
Pole elevation and layout plan
Edit inputs ↓RP-8 layout screen
Review needed- Same-side pitch / height5.46 / ≤ 4 × outside screen
Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.
Additional readings
| Luminaires per repeat | 2 |
|---|---|
| Combined light loss factor | 0.765 |
| Maintained delivered flux per repeat | 8,604.72lm |
| Area-normalized connected power | 0.036W/ft² |
| Optical overhang | 4.59ft |
| Distance to next pole station | 94.1ft |
| Pitch limit from height criterion | 137.8ft |
Worked calculation
US customary results for the original preset.
- Apply utilization and loss factors over 2 poles per repeat to get 8604.72 lm maintained.
- Divide by the road width and target illuminance to get 188.2 ft same-side pitch. The pitch-to-height ratio is 5.46.
- Scale the repeat to 56.1 poles/mi and 3.87 kW/km of linear connected power.
Calculation method
Select a maintained illuminance target for the road or parking class. Apply the street-side utilization and light loss to the flux in one repeating roadway cell.
- Maintained lumens through one cell
- Φcell = Φ × CU × LLD × LDD × fixtures per repeat
- Same-side pole pitch
- S = Φcell/(Eavg × roadway width)
- Pole density and power
- Poles/km = 1000 × fixtures per repeat/S · kW/km = poles/km × W/1000
The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.
Sources and assumptions ↗Staggered industrial drive aisle
Inputs
| Pole configuration | Staggered |
|---|---|
| Roadway width | 32.808399ft |
| Mounting height | 34.4488189ft |
| Optical overhang past curb | 4.5931759ft |
| Max pitch / mounting height | 4× |
| Output per pole | 14,800lm |
| Street-side utilization | 0.38 |
| Lumen depreciation (LLD) | 0.9 |
| Dirt depreciation (LDD) | 0.85 |
| Maintained roadway target | 1.3935456fc |
| Input per pole | 111W |
Results
| Pole pitch | 188.2ft |
|---|---|
| Pitch / height | 5.46× |
| Pole density | 56.1poles/mi |
| Linear power | 3.87kW/km |
| Luminaires per repeat | 2 |
| Combined light loss factor | 0.765 |
| Maintained delivered flux per repeat | 8,604.72lm |
| Area-normalized connected power | 0.036W/ft² |
| Optical overhang | 4.59ft |
| Distance to next pole station | 94.1ft |
| Pitch limit from height criterion | 137.8ft |
RP-8 layout screen
- Same-side pitch / height · 5.46 / ≤ 4 × · Outside screen
Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.
The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.