Wide collector road geometry

Use a relatively long calculated pitch to see when average light and the layout screen disagree.

Road and mounting
ft
ft
ft
×
Luminaire and target
lm
fc
W
Pole pitch
287.19ft
Pitch / height
9.73×
Pole density
36.8poles/mi
Linear power
3.82kW/km

Pole elevation and layout plan

Edit inputs ↓
Pole elevation and layout planCURB SECTIONROADWAY PLANH 29.53 ftOppositeArm 7.87 ftS 287.19 ftMaintained target1.02 fc
Pitch is measured along one side. A staggered arrangement offsets the opposite row by half the pitch.

RP-8 layout screen

Review needed
OutsideThresholdWithin
  • Same-side pitch / height9.73 / ≤ 3.5 × outside screen

Comparison uses the entered pitch criterion. Use the relevant RP-8 limits in a point-by-point pavement grid.

Additional readings
Luminaires per repeat2
Combined light loss factor0.765
Maintained delivered flux per repeat18,776.16lm
Area-normalized connected power0.018W/ft²
Optical overhang7.87ft
Distance to next pole station287.19ft
Pitch limit from height criterion103.35ft

Worked calculation

US customary results for the original preset.

  1. Apply utilization and loss factors over 2 poles per repeat to get 18776.16 lm maintained.
  2. Divide by the road width and target illuminance to get 287.19 ft same-side pitch. The pitch-to-height ratio is 9.73.
  3. Scale the repeat to 36.8 poles/mi and 3.82 kW/km of linear connected power.

Calculation method

Select a maintained illuminance target for the road or parking class. Apply the street-side utilization and light loss to the flux in one repeating roadway cell.

Maintained lumens through one cell
Φcell = Φ × CU × LLD × LDD × fixtures per repeat
Same-side pole pitch
S = Φcell/(Eavg × roadway width)
Pole density and power
Poles/km = 1000 × fixtures per repeat/S · kW/km = poles/km × W/1000

The supplied spacing / height limit is a project heuristic. Verify RP-8 pavement uniformity, glare, luminance, and classification using grid photometry.

Sources and assumptions ↗