Line-to-line assembly clearance

A line-to-line fit has no interference pressure at the starting temperature.

Input units
Fit pressure 0 MPa
Hub hoop 0 MPa
Press force 0 N
Slip torque 0 N·m

Anatomy

Interface section and Lamé stress field

Edit inputs
Interface section and Lamé stress fieldSchematic view with the current loads and dimensions. FIT SECTIONHUB STRESSBlue = fit interfaceHoopRadialBore to hub ODPressure p0 MPaBore hoop σθ0 MPaBore radial σr0 MPa

Screening margins

No applied load
  • Hub bore yieldingNo interference pressure
    —

Calculated values

Interface pressure p0 MPa
Peak hub hoop stress0 MPa
Axial press force at full length0 N
Static slip torque capacity0 N·m
Hub radial stress at bore0 MPa
Hub hoop stress at OD0 MPa
Hub bore von Mises stress0 MPa
Hub yield factor—
Hub heating ΔT above shaft55.556 °C

Starting result

The interface contributes zero friction capacity. Heating can still provide the entered assembly clearance.

Interface pressure p
0 MPa
Static slip torque capacity
0 N·m
Hub heating ΔT above shaft
55.556 °C

Model and assumptions

p = (δ/d)/[(H+νh)/Eh+(S−νs)/Es] · F = πdLμp · T = Fd/2

Long concentric members with open ends and uniform pressure. Yield is checked at the hub bore under plane stress. Assembly heating assumes a shaft held at its initial temperature and a constant hub expansion coefficient.

References and calculation method

Worked examples

Open the standard calculator