Worked example
For a 500 mm fixed–free screw, Euler’s effective length is 1,000 mm. At 6.2 mm root diameter and 200 GPa modulus the critical load is about 143 N. A factor of two screens the usable compression at roughly 72 N.
Shortening the unsupported span is often the first change worth testing. The buckling limit rises with the inverse square of span and the fourth power of root diameter. Tension loading leaves the Euler compression comparison inapplicable.
Driving torque 0.3638 N·m
Formulas
Lead = thread pitch × startsDriving torque = thrust × lead / (2π η) + extra dragRoot-section moment I = π d⁴ / 64Critical compressive load = π² E I / (K L)²First critical RPM = 60 β² √(E I / (ρ A L⁴)) / (2π)Screened compression limit = critical load / safety factor