ASME V Article 8 · ET model
Brass at the surface reference
A 50 kHz model for brass is evaluated exactly at the surface to establish a reference phase.
Reading the result. At depth zero the phase lag is zero and the current fraction is one. A depth-derived target frequency needs a nonzero depth.
Setup
Material
% IACS
Use 1 for a nonmagnetic material.
Test conditions
kHz
mm
×
Use 1 for standard or 3 for effective depth.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Skin depth δ
- 0.55852mm
- 3δ depth
- 1.6756mm
- J / J₀
- 100%
- Phase lag
- 0°
Within 3δ model depth
Skin depth describes current density decay in a homogeneous half-space.
- Depth / skin depth
- 0×
- Unwrapped phase lag
- 0rad
- Conductivity used
- 16.24MS/m
- Relative conductivity used
- 28% IACS
- Frequency for target d/δ
- —
- A finite target frequency requires a nonzero target depth.
Conductivity presets are nominal at room temperature. Real coil response also depends on lift-off, geometry, frequency response and local permeability. Equations and references