ASME V Article 8 · ET model
304 stainless tube wall at 10 kHz
The depth of interest is 2 mm in nominal 304 stainless steel at an assumed relative permeability of one.
Reading the result. The nominal skin depth is about 4.27 mm. Cold work and weld metallurgy can shift permeability and coil response.
Setup
Material
% IACS
Use 1 for a nonmagnetic material.
Test conditions
kHz
mm
×
Use 1 for standard or 3 for effective depth.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Skin depth δ
- 4.2658mm
- 3δ depth
- 12.797mm
- J / J₀
- 62.572%
- Phase lag
- 26.863°
Within 3δ model depth
Skin depth describes current density decay in a homogeneous half-space.
- Depth / skin depth
- 0.46885×
- Unwrapped phase lag
- 0.46885rad
- Conductivity used
- 1.392MS/m
- Relative conductivity used
- 2.4% IACS
- Frequency for target d/δ
- 45.493kHz
Conductivity presets are nominal at room temperature. Real coil response also depends on lift-off, geometry, frequency response and local permeability. Equations and references