ASME V Article 8 · ET model

304 stainless tube wall at 10 kHz

The depth of interest is 2 mm in nominal 304 stainless steel at an assumed relative permeability of one.

Reading the result. The nominal skin depth is about 4.27 mm. Cold work and weld metallurgy can shift permeability and coil response.

Setup

Material

Use 1 for a nonmagnetic material.

Test conditions

kHz
mm
×
Use 1 for standard or 3 for effective depth.
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Skin depth δ
4.2658mm
3δ depth
12.797mm
J / J₀
62.572%
Phase lag
26.863°
Within 3δ model depth

Skin depth describes current density decay in a homogeneous half-space.

Current decay and impedance phaseThe left plot follows J/J₀ with depth. The right plot wraps phase by 360° and uses the same relative current magnitude.Induction profileδ 4.2658 mmTarget depth / δ0.46885×EC decay3δ depthTarget phase
The left plot follows J/J₀ with depth. The right plot wraps phase by 360° and uses the same relative current magnitude.
Depth / skin depth
0.46885×
Unwrapped phase lag
0.46885rad
Conductivity used
1.392MS/m
Relative conductivity used
2.4% IACS
Frequency for target d/δ
45.493kHz

Conductivity presets are nominal at room temperature. Real coil response also depends on lift-off, geometry, frequency response and local permeability. Equations and references