ASME V Article 8 · ET model
Ti-6Al-4V near-surface screening
A 25 kHz coil is modeled on a 1% IACS titanium alloy with a 1 mm target depth.
Reading the result. The low nominal conductivity gives about 4.18 mm of standard penetration in the half-space model.
Setup
Material
% IACS
Use 1 for a nonmagnetic material.
Test conditions
kHz
mm
×
Use 1 for standard or 3 for effective depth.
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Skin depth δ
- 4.1796mm
- 3δ depth
- 12.539mm
- J / J₀
- 78.721%
- Phase lag
- 13.708°
Within 3δ model depth
Skin depth describes current density decay in a homogeneous half-space.
- Depth / skin depth
- 0.23926×
- Unwrapped phase lag
- 0.23926rad
- Conductivity used
- 0.58MS/m
- Relative conductivity used
- 1% IACS
- Frequency for target d/δ
- 436.73kHz
Conductivity presets are nominal at room temperature. Real coil response also depends on lift-off, geometry, frequency response and local permeability. Equations and references