NDT inspection setup guide

Choose an NDT method and verify the inputs that matter for ultrasonic, radiographic, electromagnetic and TOFD inspection worksheets.

Choose the method for the indication

MethodWhat to checkOpen a worksheet
Angle-beam UTOne-sided weld access and a reflector with a measurable sound path.Skip and depth, Wedge refraction, Beam spread
RadiographyProjection through the examined thickness with film or detector access.Ug and exposure, Shielding comparison
Eddy currentNear-surface response in a conductive part, including lift-off and material variation.Skin depth
Magnetic particleSurface and near-surface indications in a ferromagnetic part.MT current
TOFDThrough-wall sizing from distinct tip signals with probe access on both sides of a weld centerline.TOFD sizing

Check the worksheet against the reference setup

  1. Record the written technique, governing edition and native unit system. The SI and US toggles are display conversions.
  2. Confirm the actual wall, OD and scan direction. For ultrasonic methods, check calibrated velocity, beam exit, refracted angle and time zero on an appropriate reference block.
  3. Use traceable reference standards for eddy current and magnetic particle checks. Record the condition of the part, lift-off or contact, field measurement location and direction.
  4. For TOFD, mark the datum, measure PCS at beam index points, and compare lateral and backwall arrivals before reading two tip picks.

Review radiographic safety separately

Use the applicable radiation protection procedure and license. Survey the real barrier and work area with calibrated instrumentation under qualified oversight. Model results assume declared source activity, one direction of collimation and a uniform shield path.

Under U.S. NRC 10 CFR 20.1301, the unrestricted-area external dose comparison is 2 mrem in any one hour. The 2 mR/h worksheet preset is an illustrative rate. The 100 mR/h preset is a separate illustrative rate. The high-radiation-area definition uses 100 mrem in one hour at 30 cm and carries access-control requirements. Rates in mR/h describe exposure in air. Review 10 CFR 20.1003, 20.1601 and 34.49 for the U.S. context.

Record assumptions with the result

Share a URL to reproduce inputs and displayed units. Download JSON for exact machine-readable quantities, CSV for a worksheet, and SVG or PNG for the schematic. Print the active setup and readout as an A4 sheet. Record the calibrated instrument result and applicable acceptance decision in the official inspection record.

See the calculation methodology for the model equations and limitations.