ASME V Article 2 · Ug screen

RT Geometric Unsharpness & Exposure

Screen geometric unsharpness against ASME Section V thickness bands. Estimate the minimum SFD and rescale a qualified reference exposure.

Setup

Exposure geometry

mm
mm
Film-side surface in contact.
mm

Reference shot

mm
min
GBq
Activity at the reference shot.
GBq
d
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Calculated Ug
0.20563mm
ASME Ug limit
0.508mm
Minimum SFD
225.01mm
Exposure time
4.168min
Pass · within Ug limit

This verdict covers the geometric unsharpness screen only.

Focal spot projection onto filmObject is assumed in contact with the film or detector. The shaded band represents geometric penumbra.Radiographic setupContact geometryUg / thickness limit40.478%Source spotObjectFilm blur
Object is assumed in contact with the film or detector. The shaded band represents geometric penumbra.
Source-to-object distance
462mm
Ug margin to limit
0.30237mm
Inverse-square time factor
1.2346×
Source half-life
73.83d
Decay-adjusted activity
1369.9GBq
Remaining activity
74.05%
Activity correction
1.3504×

Use the project-specified Section V edition and its native limit table. The exposure estimate assumes the same object, detector and beam conditions as the reference. Verify the approved technique and image-quality indicators. Equations and references

Worked examples

Open a setup to inspect its inputs, then try your own values.