ASME V Article 4 · AWS D1.1

UT Angle-Beam Skip Distance

Locate a shear-wave reflector from its sound path. Calculate skip distance, beam leg and true depth for a flat weld or a circumferential pipe scan.

Setup

Part geometry

mm

Sound path

°
35–75° from the surface normal.
mm
m/s
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Flaw depth
13.5mm
Surface dist.
63.22mm
Half skip
43.301mm
Full skip
86.603mm
Leg 2

Surface distance starts at the beam exit point.

Weld section and shear pathPipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.Shear-wave mapFlat sectionActive leg progress46%Steel wallShear rayReflector
Pipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.
Active leg / chord
2
One leg or chord sound path
50mm
Flat-plate full skip reference
86.603mm
Pulse-echo round-trip time
45.201µs
AWS distance correction
3.748dB
Max. angle reaching pipe ID
—
OD-only chord arc advance
—
Pipe OD circumference
—

Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references

Worked examples

Open a setup to inspect its inputs, then try your own values.