Calculation methodology

Equations, assumptions and reference standards behind the eight NDTInspectLab calculators, including ASME Ug, HVL, MT and TOFD.

Ultrasonic geometry and beam models

Angle-beam skips

Flat plate · half skip = t tan θ · full skip = 2t tan θ · SD = S sin θ

Fold the through-wall component of the one-way path at each boundary to find depth and leg. Exact contact belongs to the leg ending at that surface. Circumferential pipe scans intersect the annulus at the OD and ID, then project the reflector radially onto the OD arc. A ray above arcsin(ID/OD) follows OD-only chords. The AWS inch-pound distance term is max(0, 2(S/25.4 − 1)) dB with S in mm. Use the project edition for native units and rounding. Angle-beam calculator

Snell refraction and impedance

sin θᵢ / V₁ = sin θᵣ / V₂ · Z = ρV · R = ((Z₂ − Z₁)/(Z₂ + Z₁))² · T = 1 − R

Evaluate V₂ separately for L and S. A critical angle exists when V₂ ≥ V₁. An exactly critical mode grazes at 90°. The open pure-shear window begins above L cutoff and ends at S cutoff or 90° incidence. R, T and −10 log₁₀ T describe the longitudinal normal-incidence interface. Snell calculator

Unfocused circular element

λ = V/f · N = (D² − λ²)/(4λ) · γₖ = arcsin(kλ/D) · W₋₆ = 2z tan γ₋₆

Use k = 0.514 at −6 dB and 1.08 at −20 dB. The model requires D > λ and a strictly subunit arcsine argument for each contour. The diameter uses the aperture plane as the far-field cone origin. D²/(4λ) is listed as the common large-aperture reference. Beam spread calculator

Radiographic geometry and radiation models

Ug = Ft/(SFD − t) · SFDₘᵢₙ = t + Ft/Ugₗᵢₘ · T = T₀(SFD/SFD₀)²(A₀/A)

The film-contact model uses t as both thickness and the source-side face-to-film distance. A = Aᵈ 2⁻ᵉ⁄ʰ for dated gamma activity Aᵈ, elapsed days e and half-life h. X-ray rescales distance only at the reference tube settings. Ug and exposure calculator

Thickness t, inchesUg maximum, inchesExact inch conversion, mm
t < 20.0200.508
2 ≤ t ≤ 30.0300.762
3 < t ≤ 40.0401.016
t > 40.0701.778

The table screens the specified inch-pound bands. Native SI code values may be rounded differently. Confirm the applicable edition and referenced construction code.

Transmission = 2⁻ˣ⁄ᴴⱽᴸ or 10⁻ˣ⁄ᵀⱽᴸ · rate = Γ A × transmission/(Cr²)

C ≥ 1 is the collimator divisor for the modeled direction. Solve that rate equation for radius at the entered comparison rate. Add rate × shot duration × shot count to prior modeled shift dose. Where a larger first-layer value is tabulated, the single-exponential screen uses that value across the modeled thickness. Published HVLs and TVLs can imply different curves. For rows with a single HVL the equivalent TVL is HVL × log₂(10). The mR/h view uses the rough photon modeling convention 1 mR/h ≈ 0.01 mSv/h. It connects different quantities and varies with energy and measurement conditions. Shielding calculator

Eddy-current penetration

δ = 1/√(πfμ₀μᵣσ) · J/J₀ = e⁻ᵈ⁄ᵟ · phase lag = d/δ rad

Use 58 MS/m at 100% IACS and solve for frequency with δ = d/(target d/δ). Three skin depths transmit about 5% of the surface current density. The material model assumes a homogeneous half-space with constant conductivity and permeability. Eddy-current calculator

Magnetic particle current windows

Screen circular magnetization at 300–800 A per inch of OD. Prod factors are 90–110 A/in of spacing below ¾ in thickness and 100–125 A/in at or above it. The high-fill coil uses NI = 35,000/(L/D + 2). The low-fill wall-position model uses NI = 45,000/(L/D). The worksheet uses a ±10% window and 2–15 calculation range for coil L/D. Verify edition, effective diameter, fill and current waveform before using a qualified technique.

H = I/(2πr) applies to the straight-current screening estimate. Compare a measured tangential field against the typical 30 Oe level for any mode. ASTM E1444/E1444M covers aerospace wet fluorescent testing. ASTM E3024/E3024M addresses general industry. Magnetization calculator

TOFD midline inversion and timing

tlat = PCS/VL · d = ½√((VL × τ)² − PCS²) · h = d₂ − d₁ · PCS target = 4t tan θ/3

τ is material travel time after removing the two wedge paths or adding the measured lateral-relative lag to PCS/VL. Use 2 × hypot(PCS/2, t)/VL for material backwall time. Convert the greater of sample interval and lateral pulse width into a depth above the lateral wave. The sample-only result is a lower bound for real pulse overlap. TOFD calculator

Reference basis

ASME BPVC Section V, Articles 2, 4, 7 and 8. AWS D1.1/D1.1M, Structural Welding Code—Steel. ASTM E1444/E1444M and E709. ISO 10863 and ISO 16828. Evident, Ultrasonic Flaw Detection Tutorial and Curved Surface Correction theory.

Gamma output uses IAEA SSG-11 Annex II and EPR-Medical for Cs-137. Representative shield data use IAEA Safety Reports Series No. 47 Table 22, QSA Global MAN-054 Table 2 and its Se-75 shielding data, and Li et al., Sensors (2022), Table 2. W and U combinations without a representative layer use a narrow-beam estimate from NIST elemental attenuation at 0.30 MeV for Se-75 or 0.662 MeV for Cs-137. Source loading, alloy, buildup, geometry and spectrum can change the values.