Unfocused circular transducer
UT Near Field & Beam Spread
Compute wavelength, Fresnel near-field length and the −6 dB and −20 dB half-angles for a circular ultrasonic element.
Setup
Active element
mm
MHz
Sound path
m/s
mm
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Near field N
- 33.76mm
- Wavelength
- 1.184mm
- −6 dB angle
- 2.7466°
- −20 dB angle
- 5.7787°
Target at or beyond N
The cone width uses an unfocused circular-piston approximation.
- −6 dB cone diameter at target
- 6.2367mm
- Target depth / near-field length
- 1.9253×
- D²/(4λ) reference
- 34.056mm
Use an unfocused, circular active element in a homogeneous medium. Focused probes, phased-array apertures and measured beam maps require a different model. Equations and references
Worked examples
Open a setup to inspect its inputs, then try your own values.