Unfocused circular transducer
Target at the end of the Fresnel zone
A 5 mm crystal at 6 MHz couples into a 6,000 m/s material. The reflector is 6 mm deep.
Reading the result. The wavelength is exactly 1 mm in this setup. The finite-wavelength near field is 6 mm.
Setup
Active element
mm
MHz
Sound path
m/s
mm
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Near field N
- 6mm
- Wavelength
- 1mm
- −6 dB angle
- 5.9004°
- −20 dB angle
- 12.474°
Target at or beyond N
The cone width uses an unfocused circular-piston approximation.
- −6 dB cone diameter at target
- 1.2402mm
- Target depth / near-field length
- 1×
- D²/(4λ) reference
- 6.25mm
Use an unfocused, circular active element in a homogeneous medium. Focused probes, phased-array apertures and measured beam maps require a different model. Equations and references