Unfocused circular transducer
Small element without a finite −20 dB half-angle
A 1.05 mm crystal has a 1 mm wavelength in the test material.
Reading the result. The −6 dB angle is available. The −20 dB arcsine argument is above one and the angle is left blank.
Setup
Active element
mm
MHz
Sound path
m/s
mm
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Near field N
- 0.025625mm
- Wavelength
- 1mm
- −6 dB angle
- 29.309°
- −20 dB angle
- —
Target at or beyond N
The cone width uses an unfocused circular-piston approximation.
- −6 dB cone diameter at target
- 3.3683mm
- Target depth / near-field length
- 117.07×
- D²/(4λ) reference
- 0.27563mm
- The −20 dB half-angle is unavailable because 1.08λ/D is at least 1.
Use an unfocused, circular active element in a homogeneous medium. Focused probes, phased-array apertures and measured beam maps require a different model. Equations and references