Unfocused circular transducer

Beam width at an aluminum reflector

A 5 mm transducer with a 1 mm wavelength has a reflector at 12 mm.

Reading the result. The far-field −6 dB cone projects to a diameter of about 2.48 mm at the target.

Setup

Active element

mm
MHz

Sound path

m/s
mm
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Near field N
6mm
Wavelength
1mm
−6 dB angle
5.9004°
−20 dB angle
12.474°
Target at or beyond N

The cone width uses an unfocused circular-piston approximation.

Circular aperture and beam envelopeThe cone outlines are schematic. The −6 dB width uses a far-field cone extrapolated from the element plane.Aperture profileUnfocused pistonTarget depth / N2×Near focus−6 dB−20 dB
The cone outlines are schematic. The −6 dB width uses a far-field cone extrapolated from the element plane.
−6 dB cone diameter at target
2.4803mm
Target depth / near-field length
2×
D²/(4λ) reference
6.25mm

Use an unfocused, circular active element in a homogeneous medium. Focused probes, phased-array apertures and measured beam maps require a different model. Equations and references