Unfocused circular transducer
Shallow reflector under a large aperture
A 25 mm circular crystal operates at 10 MHz in a material with a 5,000 m/s velocity. The reflector is at 20 mm.
Reading the result. The focal distance is about 312.38 mm. The target is inside the near field, where amplitude varies with depth.
Setup
Active element
mm
MHz
Sound path
m/s
mm
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Near field N
- 312.38mm
- Wavelength
- 0.5mm
- −6 dB angle
- 0.58901°
- −20 dB angle
- 1.2377°
Target in the near field
The displayed cone width is a far-field extrapolation. Near-field amplitude has local peaks and nulls.
- −6 dB cone diameter at target
- 0.41122mm
- Target depth / near-field length
- 0.064026×
- D²/(4λ) reference
- 312.5mm
Use an unfocused, circular active element in a homogeneous medium. Focused probes, phased-array apertures and measured beam maps require a different model. Equations and references