Unfocused circular transducer

Shallow reflector under a large aperture

A 25 mm circular crystal operates at 10 MHz in a material with a 5,000 m/s velocity. The reflector is at 20 mm.

Reading the result. The focal distance is about 312.38 mm. The target is inside the near field, where amplitude varies with depth.

Setup

Active element

mm
MHz

Sound path

m/s
mm
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Near field N
312.38mm
Wavelength
0.5mm
−6 dB angle
0.58901°
−20 dB angle
1.2377°
Target in the near field

The displayed cone width is a far-field extrapolation. Near-field amplitude has local peaks and nulls.

Circular aperture and beam envelopeThe cone outlines are schematic. The −6 dB width uses a far-field cone extrapolated from the element plane.Aperture profileUnfocused pistonTarget depth / N0.064026×Near focus−6 dB−20 dB
The cone outlines are schematic. The −6 dB width uses a far-field cone extrapolated from the element plane.
−6 dB cone diameter at target
0.41122mm
Target depth / near-field length
0.064026×
D²/(4λ) reference
312.5mm

Use an unfocused, circular active element in a homogeneous medium. Focused probes, phased-array apertures and measured beam maps require a different model. Equations and references