Unfocused circular transducer

Small element without a finite −20 dB half-angle

A 1.05 mm crystal has a 1 mm wavelength in the test material.

Reading the result. The −6 dB angle is available. The −20 dB arcsine argument is above one and the angle is left blank.

Setup

Active element

mm
MHz

Sound path

m/s
mm
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Near field N
0.025625mm
Wavelength
1mm
−6 dB angle
29.309°
−20 dB angle
—
Target at or beyond N

The cone width uses an unfocused circular-piston approximation.

Circular aperture and beam envelopeThe cone outlines are schematic. The −6 dB width uses a far-field cone extrapolated from the element plane.Aperture profileUnfocused pistonTarget depth / N117.07×Near focus−6 dB−20 dB
The cone outlines are schematic. The −6 dB width uses a far-field cone extrapolated from the element plane.
−6 dB cone diameter at target
3.3683mm
Target depth / near-field length
117.07×
D²/(4λ) reference
0.27563mm
  • The −20 dB half-angle is unavailable because 1.08λ/D is at least 1.

Use an unfocused, circular active element in a homogeneous medium. Focused probes, phased-array apertures and measured beam maps require a different model. Equations and references