Foundations

Gravity Dam Uplift & Stability Calculator

Screen a concrete gravity dam section for sliding, overturning, heel and toe bearing, and middle-third eccentricity under uplift and seismic loads.

Results ↓

Inputs

Monolith geometry
m
m
m
m
kN/m³
Water & uplift
m
m
Gallery parameters
1 retains the undrained excess head at the drain. 0 drains to tailwater head.
Silt, base & seismic loads
m
kN/m³
kPa

Hydraulic readout

Within the middle third

Sliding FS: 2.14655, Overturning FS: 2.73543, Heel pressure: 240.057 kPa, Toe pressure: 173.624 kPa

Gravity dam force section and foundation pressuresHydrostatic thrust diagrams, the resultant and the middle-third area are shown in section. The adjacent panel shows uplift above and bearing pressures below.SLIDING FS2.1466OVERTURN FS2.7354HEEL PRESSURE240.06 kPaTOE PRESSURE173.62 kPaMonolith and resultantThrustKernelBaseUplift & linear bearingUpliftBearingTensionResultant · middle thirde = -0.38809 m
  • Linear bearing stresses assume full rigid contact. Load combinations, foundation capacity and cracked-base uplift require separate checks.
  • Gallery uplift assumes an effective drain at foundation level. Confirm piezometric and drainage conditions.

Calculation details

Eccentricity toward toe
-0.388093 m
Kern half-width B/6
2.41667 m
Resultant from heel
6.86191 m
Concrete weight
3,823.2 kN
Reservoir thrust
1,103.25 kN
Tailwater thrust
19.6133 kN
Tailwater downward force
11.9859 kN
Total uplift
836.001 kN
Silt thrust
3.4155 kN
Dam inertia
0 kN
Westergaard thrust
0 kN
Net vertical force
2,999.18 kN
Net downstream force
1,087.05 kN
Resisting toe moment
36,108.3 kN·m
Overturning toe moment
13,200.2 kN·m
Net toe moment
22,908.1 kN·m

Calculation method

FSs = (μΣV + c B w)/ΣH · e = B/2 − Mnet/ΣV · σ = ΣV/(Bw) (1 ± 6e/B)

A vertical upstream face and a straight downstream batter define the cross section. The solver integrates piecewise linear uplift and includes tailwater’s horizontal and vertical components. Positive eccentricity points downstream.

Kernel and force balance are initial screens for a single load case. Verify regulatory load combinations, drain performance, material strengths and foundation response with qualified dam-safety review.

Worked examples

Open a case to load its inputs and interpretation.

Share worksheet