Worked example

Pseudo-static earthquake load case

A 23 m concrete monolith is checked at kₕ = 0.13 with a 19 m pool and optional Westergaard loading.

Results ↓

Inputs

Monolith geometry
m
m
m
m
kN/m³
Water & uplift
m
m
Gallery parameters
1 retains the undrained excess head at the drain. 0 drains to tailwater head.
Silt, base & seismic loads
m
kN/m³
kPa

Hydraulic readout

Within the middle third

Sliding FS: 1.40061, Overturning FS: 2.03557, Heel pressure: 148.456 kPa, Toe pressure: 384.715 kPa

Gravity dam force section and foundation pressuresHydrostatic thrust diagrams, the resultant and the middle-third area are shown in section. The adjacent panel shows uplift above and bearing pressures below.SLIDING FS1.4006OVERTURN FS2.0356HEEL PRESSURE148.46 kPaTOE PRESSURE384.72 kPaMonolith and resultantThrustKernelBaseUplift & linear bearingUpliftBearingTensionResultant · middle thirde = 1.3737 m
  • Linear bearing stresses assume full rigid contact. Load combinations, foundation capacity and cracked-base uplift require separate checks.
  • Gallery uplift assumes an effective drain at foundation level. Confirm piezometric and drainage conditions.

Calculation details

Eccentricity toward toe
1.37368 m
Kern half-width B/6
3.1 m
Resultant from heel
10.6737 m
Concrete weight
6,405.04 kN
Reservoir thrust
1,770.1 kN
Tailwater thrust
60.0657 kN
Tailwater downward force
35.5171 kN
Total uplift
1,482.07 kN
Silt thrust
3.4155 kN
Dam inertia
832.655 kN
Westergaard thrust
268.465 kN
Net vertical force
4,958.49 kN
Net downstream force
2,814.57 kN
Resisting toe moment
77,255.4 kN·m
Overturning toe moment
37,952.8 kN·m
Net toe moment
39,302.6 kN·m

Interpreting this example

Use the force table to isolate added dam inertia and reservoir thrust. This load case uses a simplified horizontal pseudo-static model.

FSs = (μΣV + c B w)/ΣH · e = B/2 − Mnet/ΣV · σ = ΣV/(Bw) (1 ± 6e/B)

A vertical upstream face and a straight downstream batter define the cross section. The solver integrates piecewise linear uplift and includes tailwater’s horizontal and vertical components. Positive eccentricity points downstream.

Kernel and force balance are initial screens for a single load case. Verify regulatory load combinations, drain performance, material strengths and foundation response with qualified dam-safety review.

Worked examples

Open a case to load its inputs and interpretation.

All cases →