Foundations
Gravity Dam Uplift & Stability Calculator
Screen a concrete gravity dam section for sliding, overturning, heel and toe bearing, and middle-third eccentricity under uplift and seismic loads.
Inputs
Hydraulic readout
Within the middle third
Sliding FS: 2.14655, Overturning FS: 2.73543, Heel pressure: 240.057 kPa, Toe pressure: 173.624 kPa
Input values
- Dam height H
- 18 m
- Crest width
- 3.5 m
- Base width B
- 14.5 m
- Monolith width
- 1 m
- Concrete unit weight
- 23.6 kN/m³
- Reservoir depth
- 15 m
- Tailwater depth
- 2 m
- Uplift distribution
- Drainage gallery
- Residual head ratio kᵤ
- 0.52
- Drain station x/B
- 0.16
- Silt depth
- 1.5 m
- Submerged silt unit weight
- 9.2 kN/m³
- Silt pressure factor Kₐ
- 0.33
- Base friction μ
- 0.72
- Base cohesion c
- 12 kPa
- Seismic coefficient kₕ
- 0
- Westergaard thrust
- Include
- Linear bearing stresses assume full rigid contact. Load combinations, foundation capacity and cracked-base uplift require separate checks.
- Gallery uplift assumes an effective drain at foundation level. Confirm piezometric and drainage conditions.
Calculation details
- Eccentricity toward toe
- -0.388093 m
- Kern half-width B/6
- 2.41667 m
- Resultant from heel
- 6.86191 m
- Concrete weight
- 3,823.2 kN
- Reservoir thrust
- 1,103.25 kN
- Tailwater thrust
- 19.6133 kN
- Tailwater downward force
- 11.9859 kN
- Total uplift
- 836.001 kN
- Silt thrust
- 3.4155 kN
- Dam inertia
- 0 kN
- Westergaard thrust
- 0 kN
- Net vertical force
- 2,999.18 kN
- Net downstream force
- 1,087.05 kN
- Resisting toe moment
- 36,108.3 kN·m
- Overturning toe moment
- 13,200.2 kN·m
- Net toe moment
- 22,908.1 kN·m
Calculation method
FSs = (μΣV + c B w)/ΣH · e = B/2 − Mnet/ΣV · σ = ΣV/(Bw) (1 ± 6e/B)
A vertical upstream face and a straight downstream batter define the cross section. The solver integrates piecewise linear uplift and includes tailwater’s horizontal and vertical components. Positive eccentricity points downstream.
Kernel and force balance are initial screens for a single load case. Verify regulatory load combinations, drain performance, material strengths and foundation response with qualified dam-safety review.
Worked examples
Open a case to load its inputs and interpretation.
- Drained gravity-dam monolithA 14.5 m base and 3.5 m crest support an 18 m monolith at normal pool. A foundation-level drain retains 52% of its undrained excess head.
- Full uplift with drains out of serviceReview a concrete dam with an 18 m base after loss of foundation drainage. Reservoir and tailwater depths are 17.0 m and 1.5 m.
- Pseudo-static earthquake load caseA 23 m concrete monolith is checked at kₕ = 0.13 with a 19 m pool and optional Westergaard loading.
- Heel tension in a slender damA preliminary 16 m tall section has a 7.2 m base, a 2.2 m crest and 14 m of reservoir depth with full uplift.
- Gravity dam with high tailwaterCheck the 18 m section with reservoir depth 15.0 m and a temporary 10 m downstream pool.