Worked example
Heel tension in a slender dam
A preliminary 16 m tall section has a 7.2 m base, a 2.2 m crest and 14 m of reservoir depth with full uplift.
Inputs
Hydraulic readout
Sliding resistance exceeded
Sliding FS: 0.88231, Overturning FS: 1.19023, Heel pressure: -198.934 kPa, Toe pressure: 549.822 kPa
Input values
- Dam height H
- 16 m
- Crest width
- 2.2 m
- Base width B
- 7.2 m
- Monolith width
- 1 m
- Concrete unit weight
- 23.6 kN/m³
- Reservoir depth
- 14 m
- Tailwater depth
- 0.5 m
- Uplift distribution
- Full linear uplift
- Silt depth
- 1.5 m
- Submerged silt unit weight
- 9.2 kN/m³
- Silt pressure factor Kₐ
- 0.33
- Base friction μ
- 0.65
- Base cohesion c
- 4 kPa
- Seismic coefficient kₕ
- 0
- Westergaard thrust
- Include
- Heel tension indicates loss of contact. Recompute uplift and stresses with a cracked-base model.
- Linear bearing stresses assume full rigid contact. Load combinations, foundation capacity and cracked-base uplift require separate checks.
Calculation details
- Eccentricity toward toe
- 2.56067 m
- Kern half-width B/6
- 1.2 m
- Resultant from heel
- 6.16067 m
- Concrete weight
- 1,774.72 kN
- Reservoir thrust
- 961.052 kN
- Tailwater thrust
- 1.22583 kN
- Tailwater downward force
- 0.383072 kN
- Total uplift
- 511.907 kN
- Silt thrust
- 3.4155 kN
- Dam inertia
- 0 kN
- Westergaard thrust
- 0 kN
- Net vertical force
- 1,263.2 kN
- Net downstream force
- 963.241 kN
- Resisting toe moment
- 8,214.28 kN·m
- Overturning toe moment
- 6,901.41 kN·m
- Net toe moment
- 1,312.88 kN·m
Interpreting this example
Negative linear heel pressure signals contact loss. The listed pressure pair gives the full-contact trial for a follow-up cracked-base analysis.
FSs = (μΣV + c B w)/ΣH · e = B/2 − Mnet/ΣV · σ = ΣV/(Bw) (1 ± 6e/B)
A vertical upstream face and a straight downstream batter define the cross section. The solver integrates piecewise linear uplift and includes tailwater’s horizontal and vertical components. Positive eccentricity points downstream.
Kernel and force balance are initial screens for a single load case. Verify regulatory load combinations, drain performance, material strengths and foundation response with qualified dam-safety review.
Worked examples
Open a case to load its inputs and interpretation.
- Drained gravity-dam monolithA 14.5 m base and 3.5 m crest support an 18 m monolith at normal pool. A foundation-level drain retains 52% of its undrained excess head.
- Full uplift with drains out of serviceReview a concrete dam with an 18 m base after loss of foundation drainage. Reservoir and tailwater depths are 17.0 m and 1.5 m.
- Pseudo-static earthquake load caseA 23 m concrete monolith is checked at kₕ = 0.13 with a 19 m pool and optional Westergaard loading.
- Gravity dam with high tailwaterCheck the 18 m section with reservoir depth 15.0 m and a temporary 10 m downstream pool.