Worked example

Free sluice underflow

A 2.8 m turnout gate is raised 0.32 m under a 2.45 m upstream pool. Tailwater is 0.44 m deep.

Results ↓

Inputs

Control type
Underflow gate
m
m
m
m

Hydraulic readout

Free-flow gate

Discharge: 3.64628 m³/s, Contracted jet: 0.1952 m, Drowning depth: 1.23706 m, Jet velocity: 6.67133 m/s

Sluice gate underflow and tailwater transitionThe contraction narrows the jet beneath the gate. Discharge drops beyond the conjugate tailwater threshold.DISCHARGE3.6463 m³/sCONTRACTED JET0.1952 mDROWNING DEPTH1.2371 mJET VELOCITY6.6713 m/sUnderflow sectionJet flowTailwaterGateDischarge vs. tailwaterRatingThresholdDepth yₜ →Tailwater vs. conjugate0.44 m / 1.2371 m
  • Free flow uses a lossless rectangular approach to the vena contracta. The submerged branch is a differential-head screen, matched at incipient drowning. Field ratings depend on gate geometry.

Calculation details

Free discharge
3.64628 m³/s
Free jet Froude
4.82183
Gate opening
0.32 m
Tailwater depth
0.44 m

Interpreting this example

Tailwater is below the free jet’s conjugate depth. The contraction coefficient governs the initial jet area.

Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a

The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.

Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.

Worked examples

Open a case to load its inputs and interpretation.

All cases →