Worked example

Ogee crest with a shallow approach

A 24 ft vertical-face overflow crest stands 1.6 ft above the approach invert. Both design and operating energy heads are 5.5 ft.

Results ↓

Inputs

Control type
Overflow crest
ft
ft
ft
ft
Crest height over the upstream approach invert.

Hydraulic readout

Free overflow

Discharge: 1,138.93 cfs, Head ratio: 1, C / Cᵈ: 1, Coefficient: 3.67909 ft½/s

Ogee crest section and discharge coefficientDownstream coordinates are plotted with a scaled crest profile. The chart marks the current operating head ratio and the pressure screen.DISCHARGE1,138.9 cfsHEAD RATIO1C / Cᵈ1COEFFICIENT3.6791 ft½/sOverflow profileNappeOgeeHₑ & POperating coefficient C/CᵈChart fitWarningHₑ/Hᵈ →Operating head ratio1 / 1.33
  • Width is effective after pier and abutment contractions. The rating assumes a vertical upstream face and unimpeded overflow.

Calculation details

Design coefficient
3.67909 ft½/s
Effective crest width
24 ft
Design energy head
5.5 ft
Operating energy head
5.5 ft
Apron depth
1.6 ft

Downstream ogee crest coordinates

X / HᵈStation XftDrop Yft
000
0.251.3750.2116
0.52.750.76283
0.754.1251.6151
15.52.75
1.256.8754.1554
1.58.255.8224
1.759.6257.7438
2119.9138
2.2512.37512.327
2.513.7514.98

Interpreting this example

The approach depth is small relative to design head. Compare the base coefficient against a high-apron crest before using the rating.

Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a

The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.

Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.

Worked examples

Open a case to load its inputs and interpretation.

All cases →