Worked example
Ogee crest with a shallow approach
A 24 ft vertical-face overflow crest stands 1.6 ft above the approach invert. Both design and operating energy heads are 5.5 ft.
Inputs
Hydraulic readout
Free overflow
Discharge: 1,138.93 cfs, Head ratio: 1, C / Cᵈ: 1, Coefficient: 3.67909 ft½/s
Input values
- Structure
- Ogee spillway
- Effective crest width L
- 24 ft
- Design energy head Hᵈ
- 5.5 ft
- Operating energy head Hₑ
- 5.5 ft
- Upstream apron depth P
- 1.6 ft
- Width is effective after pier and abutment contractions. The rating assumes a vertical upstream face and unimpeded overflow.
Calculation details
- Design coefficient
- 3.67909 ft½/s
- Effective crest width
- 24 ft
- Design energy head
- 5.5 ft
- Operating energy head
- 5.5 ft
- Apron depth
- 1.6 ft
Downstream ogee crest coordinates
| X / Hᵈ | Station Xft | Drop Yft |
|---|---|---|
| 0 | 0 | 0 |
| 0.25 | 1.375 | 0.2116 |
| 0.5 | 2.75 | 0.76283 |
| 0.75 | 4.125 | 1.6151 |
| 1 | 5.5 | 2.75 |
| 1.25 | 6.875 | 4.1554 |
| 1.5 | 8.25 | 5.8224 |
| 1.75 | 9.625 | 7.7438 |
| 2 | 11 | 9.9138 |
| 2.25 | 12.375 | 12.327 |
| 2.5 | 13.75 | 14.98 |
Interpreting this example
The approach depth is small relative to design head. Compare the base coefficient against a high-apron crest before using the rating.
Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a
The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.
Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.
Worked examples
Open a case to load its inputs and interpretation.
- Ogee overflow at design headA 12 m effective crest operates at its 1.4 m design energy head with 4.7 m of upstream apron depth.
- Overflow above the design headA 16 m spillway shaped for a 1.7 m design head experiences a 2.4 m total energy head.
- Free sluice underflowA 2.8 m turnout gate is raised 0.32 m under a 2.45 m upstream pool. Tailwater is 0.44 m deep.
- Drowned sluice in a control bayA 3.6 m gate has an 0.48 m opening, 3.15 m upstream depth and 2.6 m receiving-pool depth.
- Low head difference at a sluiceTwo pools separated by a 5 ft gate have depths of 8.2 ft and 8.0 ft. The opening is 0.9 ft.