Worked example

Low head difference at a sluice

Two pools separated by a 5 ft gate have depths of 8.2 ft and 8.0 ft. The opening is 0.9 ft.

Results ↓

Inputs

Control type
Underflow gate
ft
ft
ft
ft

Hydraulic readout

Submerged gate

Discharge: 12.8304 cfs, Contracted jet: 0.54 ft, Drowning depth: 3.81541 ft, Jet velocity: 4.752 ft/s

Sluice gate underflow and tailwater transitionThe contraction narrows the jet beneath the gate. Discharge drops beyond the conjugate tailwater threshold.DISCHARGE12.83 cfsCONTRACTED JET0.54 ftDROWNING DEPTH3.8154 ftJET VELOCITY4.752 ft/sUnderflow sectionJet flowTailwaterGateDischarge vs. tailwaterRatingThresholdDepth yₜ →Tailwater vs. conjugate8 ft / 3.8154 ft
  • Free flow uses a lossless rectangular approach to the vena contracta. The submerged branch is a differential-head screen, matched at incipient drowning. Field ratings depend on gate geometry.

Calculation details

Free discharge
60.0744 cfs
Free jet Froude
5.33797
Gate opening
0.9 ft
Tailwater depth
8 ft

Interpreting this example

A small driving head makes gauge accuracy important. The submerged branch approaches zero discharge as the pool levels converge.

Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a

The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.

Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet