Worked example

Drowned sluice in a control bay

A 3.6 m gate has an 0.48 m opening, 3.15 m upstream depth and 2.6 m receiving-pool depth.

Results ↓

Inputs

Control type
Underflow gate
m
m
m
m

Hydraulic readout

Submerged gate

Discharge: 4.97144 m³/s, Contracted jet: 0.2976 m, Drowning depth: 1.70814 m, Jet velocity: 4.64031 m/s

Sluice gate underflow and tailwater transitionThe contraction narrows the jet beneath the gate. Discharge drops beyond the conjugate tailwater threshold.DISCHARGE4.9714 m³/sCONTRACTED JET0.2976 mDROWNING DEPTH1.7081 mJET VELOCITY4.6403 m/sUnderflow sectionJet flowTailwaterGateDischarge vs. tailwaterRatingThresholdDepth yₜ →Tailwater vs. conjugate2.6 m / 1.7081 m
  • Free flow uses a lossless rectangular approach to the vena contracta. The submerged branch is a differential-head screen, matched at incipient drowning. Field ratings depend on gate geometry.

Calculation details

Free discharge
8.04939 m³/s
Free jet Froude
4.39795
Gate opening
0.48 m
Tailwater depth
2.6 m

Interpreting this example

Tailwater exceeds the conjugate threshold and reduces the estimated gate discharge. Confirm the rating over observed downstream levels.

Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a

The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.

Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.

Worked examples

Open a case to load its inputs and interpretation.

All cases →