Worked example
Drowned sluice in a control bay
A 3.6 m gate has an 0.48 m opening, 3.15 m upstream depth and 2.6 m receiving-pool depth.
Inputs
Hydraulic readout
Submerged gate
Discharge: 4.97144 m³/s, Contracted jet: 0.2976 m, Drowning depth: 1.70814 m, Jet velocity: 4.64031 m/s
Input values
- Structure
- Sluice gate
- Gate opening a
- 0.48 m
- Gate width B
- 3.6 m
- Upstream depth y₁
- 3.15 m
- Tailwater depth yₜ
- 2.6 m
- Contraction coefficient C꜀
- 0.62
- Free flow uses a lossless rectangular approach to the vena contracta. The submerged branch is a differential-head screen, matched at incipient drowning. Field ratings depend on gate geometry.
Calculation details
- Free discharge
- 8.04939 m³/s
- Free jet Froude
- 4.39795
- Gate opening
- 0.48 m
- Tailwater depth
- 2.6 m
Interpreting this example
Tailwater exceeds the conjugate threshold and reduces the estimated gate discharge. Confirm the rating over observed downstream levels.
Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a
The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.
Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.
Worked examples
Open a case to load its inputs and interpretation.
- Ogee overflow at design headA 12 m effective crest operates at its 1.4 m design energy head with 4.7 m of upstream apron depth.
- Ogee crest with a shallow approachA 24 ft vertical-face overflow crest stands 1.6 ft above the approach invert. Both design and operating energy heads are 5.5 ft.
- Overflow above the design headA 16 m spillway shaped for a 1.7 m design head experiences a 2.4 m total energy head.
- Free sluice underflowA 2.8 m turnout gate is raised 0.32 m under a 2.45 m upstream pool. Tailwater is 0.44 m deep.
- Low head difference at a sluiceTwo pools separated by a 5 ft gate have depths of 8.2 ft and 8.0 ft. The opening is 0.9 ft.