Worked example

Short exit element and boil risk

A downstream sheet pile has a last equipotential spacing of only 0.12 m under 3.6 m of net head with 14 drops.

Results ↓

Inputs

Flow net
m
m/s
m
Foundation geometry
m
m
m
Material

Hydraulic readout

Piping boil threshold exceeded

Unit seepage: 1.15714e-5 m²/s, Lane ratio: 7.33333, Exit gradient: 2.14286, Boiling FS: 0.463855

Foundation seepage and exit-gradient screensThe illustrative flow net wraps under the cutoff walls. Right-hand bars compare the exit gradient and weighted creep ratio with their screening thresholds.UNIT SEEPAGE1.1571e-5 m²/sLANE RATIO7.3333EXIT GRADIENT2.1429BOILING FS0.46386Cutoffs & schematic flow netFlowlinesDropsExitPiping and creep checksExit / critical gradientLane / material limitThresholdPassReviewExit gradient safety factor0.46386 / 4.0
  • Use an independently drawn flow net for homogeneous, isotropic seepage. Lane’s ratio screens empirical piping progression.

Calculation details

Lane material threshold
8.5
Critical gradient
0.993976
Target boiling factor
4
Mean floor head gradient
0.133333
Head drop per element
0.257143 m
Heel uplift above tailwater
35.3039 kPa
Horizontal creep
27 m
Vertical creep
17.4 m

Interpreting this example

Shorter spacing steepens the exit gradient even if the total flow net shows a low seepage rate. Check the granular boiling factor.

q = k ΔH Nf/Nd · Cw = (ΣLₕ/3 + ΣLᵥ)/ΔH · FS = [(Gₛ − 1)/(1 + e)] / iₑ

The last equipotential drop divided by its local spacing estimates the exit gradient. Lane’s method assigns a one-third weight to horizontal paths and full weight to vertical paths.

The USBR 4.0 exit-gradient screen is for cohesionless quick conditions in new or remedial dam work. Filters, uplift, stratification, anisotropy and concentrated leakage require separate checks.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet