Worked example

Lane screening on hard clay

A short hydraulic structure on hard clay has a 9.8 m floor, two shallow cutoffs and 1.7 m net head.

Results ↓

Inputs

Flow net
m
m/s
m
Foundation geometry
m
m
m
Material

Hydraulic readout

Cohesive uplift review

Unit seepage: 1.7e-8 m²/s, Lane ratio: 5.56863, Exit gradient: 0.244253, Boiling FS: 3.65151

Foundation seepage and exit-gradient screensThe illustrative flow net wraps under the cutoff walls. Right-hand bars compare the exit gradient and weighted creep ratio with their screening thresholds.UNIT SEEPAGE1.7e-8 m²/sLANE RATIO5.5686EXIT GRADIENT0.24425BOILING FS3.6515Cutoffs & schematic flow netFlowlinesDropsExitPiping and creep checksExit / critical gradientLane / material limitThresholdPassReviewExit gradient safety factor3.6515 / 4.0
  • Use an independently drawn flow net for homogeneous, isotropic seepage. Lane’s ratio screens empirical piping progression.
  • The granular quick-condition factor is illustrative for cohesive material. Check cohesive blanket uplift separately.

Calculation details

Lane material threshold
1.8
Critical gradient
0.891892
Target boiling factor
4
Mean floor head gradient
0.173469
Head drop per element
0.141667 m
Heel uplift above tailwater
16.6713 kPa
Horizontal creep
9.8 m
Vertical creep
6.2 m

Interpreting this example

The historic creep threshold is shown for the material. Assess cohesive uplift separately from the granular quick-condition calculation.

q = k ΔH Nf/Nd · Cw = (ΣLₕ/3 + ΣLᵥ)/ΔH · FS = [(Gₛ − 1)/(1 + e)] / iₑ

The last equipotential drop divided by its local spacing estimates the exit gradient. Lane’s method assigns a one-third weight to horizontal paths and full weight to vertical paths.

The USBR 4.0 exit-gradient screen is for cohesionless quick conditions in new or remedial dam work. Filters, uplift, stratification, anisotropy and concentrated leakage require separate checks.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet