Worked example
Short exit element and boil risk
A downstream sheet pile has a last equipotential spacing of only 0.12 m under 3.6 m of net head with 14 drops.
Inputs
Hydraulic readout
Piping boil threshold exceeded
Unit seepage: 1.15714e-5 m²/s, Lane ratio: 7.33333, Exit gradient: 2.14286, Boiling FS: 0.463855
Input values
- Net hydraulic head ΔH
- 3.6 m
- Permeability k
- 1.5e-5 m/s
- Flow channels Nf
- 3
- Equipotential drops Nd
- 14
- Exit element thickness Δl
- 0.12 m
- Floor length
- 27 m
- Upstream cutoff depth
- 4.5 m
- Downstream cutoff depth
- 4.2 m
- Creep length basis
- Floor and cutoffs
- Lane material screen
- Very fine sand / silt · 8.5
- Grain specific gravity Gₛ
- 2.65
- Void ratio e
- 0.66
- Use an independently drawn flow net for homogeneous, isotropic seepage. Lane’s ratio screens empirical piping progression.
Calculation details
- Lane material threshold
- 8.5
- Critical gradient
- 0.993976
- Target boiling factor
- 4
- Mean floor head gradient
- 0.133333
- Head drop per element
- 0.257143 m
- Heel uplift above tailwater
- 35.3039 kPa
- Horizontal creep
- 27 m
- Vertical creep
- 17.4 m
Interpreting this example
Shorter spacing steepens the exit gradient even if the total flow net shows a low seepage rate. Check the granular boiling factor.
q = k ΔH Nf/Nd · Cw = (ΣLₕ/3 + ΣLᵥ)/ΔH · FS = [(Gₛ − 1)/(1 + e)] / iₑ
The last equipotential drop divided by its local spacing estimates the exit gradient. Lane’s method assigns a one-third weight to horizontal paths and full weight to vertical paths.
The USBR 4.0 exit-gradient screen is for cohesionless quick conditions in new or remedial dam work. Filters, uplift, stratification, anisotropy and concentrated leakage require separate checks.
Worked examples
Open a case to load its inputs and interpretation.
- Cutoff weir on very fine sandA 24 m floor and two cutoff walls act across 2.7 m of net head. The interpreted flow net has 4 channels and 16 drops.
- Measured foundation creep pathAs-built dimensions give 31 m of horizontal path and 15 m of vertical path through a medium-sand foundation.
- Lane screening on hard clayA short hydraulic structure on hard clay has a 9.8 m floor, two shallow cutoffs and 1.7 m net head.
- Conservative fine-sand screenA 35 m floor with shallow cutoffs was assessed under a 2.95 m head. Select the project’s conservative 8.5 creep requirement.