Worked example

60° V-notch on a small turnout

A small turnout box has a 60° notch and an upstream gauge reading of 0.13 m.

Results ↓

Inputs

Measuring device
m
For Parshall flumes use the standard Hₐ tap.
m
Above crest for weirs or Hᵦ at the flume tap. Enter 0 for no positive downstream head.
Notch dimensions

Hydraulic readout

Free-flow rating

Free discharge: 0.00490206 m³/s, Villemonte Q: 0.00490206 m³/s, Submergence ratio: 0%, Comparison limit: 60%

Measuring structure geometry and free ratingH₁ and H₂ are measured from the prescribed device datums. The rating curve shows free discharge versus upstream head.FREE FLOW0.0049021 m³/sVILLEMONTE Q0.0049021 m³/sSUBMERGENCE0%SCREEN LIMIT60%Measuring crestHead H₁Head H₂CrestFree discharge Q(H₁)RatingH₁ pointHead H₁ →Tailwater ratio0% / 60%
  • Cₑ and the head offset use the Kindsvater–Shen fully contracted thin-plate curves. Provide a ventilated nappe.

Calculation details

Applicable screening rating
0.00490206 m³/s
Head exponent
2.5
Villemonte multiplier
1
V-notch effective coefficient
0.577
V-notch head correction
0.00115824 m

Interpreting this example

A narrower angle passes less flow at equal head. Use fully contracted geometry and inspect the nappe at low heads.

Qfree ∝ H₁ⁿ · Qsub / Qfree = [1 − (H₂/H₁)ⁿ]⁰·³⁸⁵

Francis subtracts 0.1H₁ per contracted end. Kindsvater–Shen uses an angle-dependent effective coefficient and head correction. Parshall sizes use the USBR Table 8-6 calibration in feet and cfs.

The 60% weir marker is a comparison screen. Use the USBR correction charts when Hᵦ/Hₐ exceeds 70% for these Parshall sizes. Check approach conditions, nappe ventilation and calibration limits.