Worked example

Suppressed rectangular lab weir

A full-width, ventilated thin-plate weir spans a 1.1 m test channel with 0.24 m of measured head.

Results ↓

Inputs

Measuring device
m
For Parshall flumes use the standard Hₐ tap.
m
Above crest for weirs or Hᵦ at the flume tap. Enter 0 for no positive downstream head.
Crest dimensions
m

Hydraulic readout

Free-flow rating

Free discharge: 0.237772 m³/s, Villemonte Q: 0.237772 m³/s, Submergence ratio: 0%, Comparison limit: 60%

Measuring structure geometry and free ratingH₁ and H₂ are measured from the prescribed device datums. The rating curve shows free discharge versus upstream head.FREE FLOW0.23777 m³/sVILLEMONTE Q0.23777 m³/sSUBMERGENCE0%SCREEN LIMIT60%Measuring crestHead H₁Head H₂CrestFree discharge Q(H₁)RatingH₁ pointHead H₁ →Tailwater ratio0% / 60%

Calculation details

Applicable screening rating
0.237772 m³/s
Effective width
1.1 m
Head exponent
1.5
Villemonte multiplier
1

Interpreting this example

The free rating uses the full crest length. Confirm that the underside of the nappe stays ventilated.

Qfree ∝ H₁ⁿ · Qsub / Qfree = [1 − (H₂/H₁)ⁿ]⁰·³⁸⁵

Francis subtracts 0.1H₁ per contracted end. Kindsvater–Shen uses an angle-dependent effective coefficient and head correction. Parshall sizes use the USBR Table 8-6 calibration in feet and cfs.

The 60% weir marker is a comparison screen. Use the USBR correction charts when Hᵦ/Hₐ exceeds 70% for these Parshall sizes. Check approach conditions, nappe ventilation and calibration limits.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet