Worked example

Two-end Francis weir

A 5 ft clear crest in a wider approach channel has two contracted ends and 0.85 ft of water head.

Results ↓

Inputs

Measuring device
ft
For Parshall flumes use the standard Hₐ tap.
ft
Above crest for weirs or Hᵦ at the flume tap. Enter 0 for no positive downstream head.
Crest dimensions
ft
End contractions

Hydraulic readout

Free-flow rating

Free discharge: 12.6043 cfs, Villemonte Q: 12.6043 cfs, Submergence ratio: 0%, Comparison limit: 60%

Measuring structure geometry and free ratingH₁ and H₂ are measured from the prescribed device datums. The rating curve shows free discharge versus upstream head.FREE FLOW12.604 cfsVILLEMONTE Q12.604 cfsSUBMERGENCE0%SCREEN LIMIT60%Measuring crestHead H₁Head H₂CrestFree discharge Q(H₁)RatingH₁ pointHead H₁ →Tailwater ratio0% / 60%

Calculation details

Applicable screening rating
12.6043 cfs
Effective width
4.83 ft
Head exponent
1.5
Villemonte multiplier
1

Interpreting this example

For two ends the effective length is reduced by 0.2H₁. Confirm the gauge location and approach clearance.

Qfree ∝ H₁ⁿ · Qsub / Qfree = [1 − (H₂/H₁)ⁿ]⁰·³⁸⁵

Francis subtracts 0.1H₁ per contracted end. Kindsvater–Shen uses an angle-dependent effective coefficient and head correction. Parshall sizes use the USBR Table 8-6 calibration in feet and cfs.

The 60% weir marker is a comparison screen. Use the USBR correction charts when Hᵦ/Hₐ exceeds 70% for these Parshall sizes. Check approach conditions, nappe ventilation and calibration limits.